Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsNAICS | 3279 | Other Nonmetallic Mineral Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0584 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,115 | $6,560 | Not Implemented |
AM0584 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $610 | $100 | Implemented |
AM0584 # 07 Y:2010 | 07 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $880 | $135 | Implemented |
AM0584 # 06 Y:2010 | 06 | 2010 | PAY UTILITY BILLS ON TIME | $1,680 | $0 | Implemented |
AM0584 # 04 Y:2010 | 04 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,880 | $0 | Not Implemented |
AM0584 # 03 Y:2010 | 03 | 2010 | USE SYNTHETIC LUBRICANT | $10,225 | $0 | Not Implemented |
AM0584 # 02 Y:2010 | 02 | 2010 | INCREASE USE OF AUTOMATION | $28,100 | $14,000 | Not Implemented |
AM0584 # 01 Y:2010 | 01 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $50,440 | $125,600 | Implemented |
UF0438 # 07 Y:2010 | 07 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,023 | $3,670 | Not Implemented |
UF0438 # 12 Y:2010 | 12 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,717 | $0 | Not Implemented |
UF0438 # 11 Y:2010 | 11 | 2010 | REPAIR OR REPLACE STEAM TRAPS | $14,482 | $0 | Not Implemented |
UF0438 # 10 Y:2010 | 10 | 2010 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $14,054 | $0 | Not Implemented |
UF0438 # 09 Y:2010 | 09 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $59,220 | $44,118 | Not Implemented |
UF0438 # 08 Y:2010 | 08 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,272 | $2,160 | Not Implemented |
UF0438 # 06 Y:2010 | 06 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $24,615 | $975 | Not Implemented |
UF0438 # 05 Y:2010 | 05 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $112,650 | $154,062 | Not Implemented |
UF0438 # 04 Y:2010 | 04 | 2010 | AIR CONDITION ONLY SPACE NECESSARY | $10,754 | $22,000 | Not Implemented |
UF0438 # 03 Y:2010 | 03 | 2010 | AIR CONDITION ONLY SPACE NECESSARY | $15,093 | $1,615 | Not Implemented |
UF0438 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $85,202 | $72,075 | Not Implemented |
UF0438 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $22,343 | $1,105 | Not Implemented |
NC0410 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $101,033 | $272,411 | Not Implemented |
NC0410 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,167 | $3,040 | Not Implemented |
NC0410 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,826 | $100 | Not Implemented |
NC0410 # 03 Y:2010 | 03 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $569 | $580 | Not Implemented |
NC0410 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $118 | $435 | Not Implemented |