Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
142
matching recommendationsNAICS | 327993 | Mineral Wool Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0594 # 08 Y:2020 | 08 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,704 | $1,950 | Implemented |
WV0594 # 10 Y:2020 | 10 | 2020 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,131 | $0 | Not Implemented |
WV0594 # 02 Y:2020 | 02 | 2020 | USE STEAM PRESSURE REDUCTION TO GENERATE POWER | $94,912 | $539,790 | Not Implemented |
WV0594 # 01 Y:2020 | 01 | 2020 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $126,819 | $150,000 | Not Implemented |
WV0554 # 06 Y:2018 | 06 | 2018 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $6,147 | $21,264 | Implemented |
WV0554 # 10 Y:2018 | 10 | 2018 | INSTALL SET-BACK TIMERS | $974 | $2,132 | Not Implemented |
WV0554 # 05 Y:2018 | 05 | 2018 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,868 | $1,000 | Implemented |
WV0554 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,081 | $5,593 | Implemented |
WV0554 # 09 Y:2018 | 09 | 2018 | MINIMIZE WATER USAGE | $1,354 | $700 | Implemented |
WV0554 # 03 Y:2018 | 03 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $16,149 | $77,350 | Not Implemented |
WV0554 # 02 Y:2018 | 02 | 2018 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $17,639 | $30,000 | Implemented |
WV0554 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,731 | $32,581 | Not Implemented |
WV0554 # 11 Y:2018 | 11 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $424 | $133 | Implemented |
WV0554 # 12 Y:2018 | 12 | 2018 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $221 | $516 | Implemented |
WV0554 # 04 Y:2018 | 04 | 2018 | INSULATE BARE EQUIPMENT | $16,102 | $29,747 | Not Implemented |
WV0554 # 08 Y:2018 | 08 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $1,406 | $632 | Implemented |
UM0459 # 01 Y:2015 | 01 | 2015 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $115,156 | $525,000 | Not Implemented |
UM0459 # 03 Y:2015 | 03 | 2015 | ADJUST BURNERS FOR EFFICIENT OPERATION | $299,710 | $30,000 | Implemented |
UM0459 # 02 Y:2015 | 02 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $982 | $800 | Not Implemented |
UD0925 # 08 Y:2015 | 08 | 2015 | INSTALL SENSORS TO DETECT AND AVOID JAMS | $7,714 | $120,000 | Implemented |
UD0925 # 01 Y:2015 | 01 | 2015 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $860 | $0 | Implemented |
UD0925 # 02 Y:2015 | 02 | 2015 | INSULATE BARE EQUIPMENT | $221,454 | $15,345 | Not Implemented |
UD0925 # 03 Y:2015 | 03 | 2015 | USE OPTIMUM TEMPERATURE | $46,665 | $0 | Not Implemented |
UD0925 # 04 Y:2015 | 04 | 2015 | UPGRADE CONTROLS ON COMPRESSORS | $4,804 | $34,000 | Not Implemented |
UD0925 # 05 Y:2015 | 05 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,759 | $5,000 | Not Implemented |