Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,664
matching recommendationsNAICS | 331 | Primary Metal Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0086 # 05 Y:2004 | 05 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,099 | $2,050 | Implemented |
IC0086 # 06 Y:2004 | 06 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,738 | $43,650 | Implemented |
IC0086 # 07 Y:2004 | 07 | 2004 | UPGRADE CONTROLS ON COMPRESSORS | $9,924 | $1,130 | Not Implemented |
IC0086 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,905 | $2,900 | Implemented |
LM0080 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $621 | $475 | Implemented |
LM0080 # 02 Y:2004 | 02 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $266 | $165 | Not Implemented |
LM0080 # 03 Y:2004 | 03 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $537 | $0 | Implemented |
LM0080 # 04 Y:2004 | 04 | 2004 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $28,600 | $20,592 | Not Implemented |
LM0080 # 05 Y:2004 | 05 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $3,467 | $6,000 | Not Implemented |
LM0080 # 06 Y:2004 | 06 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $23,164 | $300 | Implemented |
LM0080 # 07 Y:2004 | 07 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $869 | $0 | Not Implemented |
AS0383 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $842 | $200 | Not Implemented |
AS0383 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,498 | $120 | Not Implemented |
AS0383 # 03 Y:2004 | 03 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $16,320 | $40,000 | Not Implemented |
AS0383 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $2,878 | $1,350 | Not Implemented |
AS0383 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,064 | $12,003 | Not Implemented |
AS0383 # 06 Y:2004 | 06 | 2004 | COVER OPEN TANKS | $4,988 | $6,000 | Not Implemented |
AS0383 # 07 Y:2004 | 07 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $244 | $600 | Not Implemented |
AS0383 # 08 Y:2004 | 08 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,942 | $600 | Not Implemented |
AS0383 # 09 Y:2004 | 09 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $406 | $367 | Not Implemented |
AS0383 # 10 Y:2004 | 10 | 2004 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $577,735 | $9,735 | Not Implemented |
LL0192 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $61,254 | $2,590 | Implemented |
LL0192 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $55,907 | $0 | Not Implemented |
LL0192 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $41,577 | $4,400 | Implemented |
LL0192 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $21,326 | $420 | Not Implemented |