Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,725
matching recommendationsNAICS | 331 | Primary Metal Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0383 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $2,878 | $1,350 | Not Implemented |
AS0383 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,064 | $12,003 | Not Implemented |
AS0383 # 06 Y:2004 | 06 | 2004 | COVER OPEN TANKS | $4,988 | $6,000 | Not Implemented |
AS0383 # 07 Y:2004 | 07 | 2004 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $244 | $600 | Not Implemented |
AS0383 # 08 Y:2004 | 08 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $2,942 | $600 | Not Implemented |
AS0383 # 09 Y:2004 | 09 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $406 | $367 | Not Implemented |
AS0383 # 10 Y:2004 | 10 | 2004 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $577,735 | $9,735 | Not Implemented |
LL0192 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $61,254 | $2,590 | Implemented |
LL0192 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $55,907 | $0 | Not Implemented |
LL0192 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $41,577 | $4,400 | Implemented |
LL0192 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $21,326 | $420 | Not Implemented |
LL0192 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,708 | $2,585 | Implemented |
LL0192 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $3,529 | $720 | Not Implemented |
LL0192 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $2,881 | $911 | Not Implemented |
LL0192 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,610 | $6,030 | Not Implemented |
IC0084 # 01 Y:2004 | 01 | 2004 | INCREASE AMOUNT OF CONDENSATE RETURNED | $144,862 | $13,907 | Not Implemented |
IC0084 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES | $105 | $0 | Implemented |
IC0084 # 03 Y:2004 | 03 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,035 | $400 | Implemented |
IC0084 # 04 Y:2004 | 04 | 2004 | REPAIR AND ELIMINATE STEAM LEAKS | $4,809 | $585 | Implemented |
IC0084 # 05 Y:2004 | 05 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $18,612 | $4,021 | Not Implemented |
IC0084 # 06 Y:2004 | 06 | 2004 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $943 | $582,998 | Implemented |
IC0084 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $2,024 | $430,000 | Not Implemented |
IC0084 # 08 Y:2004 | 08 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $48,922 | $200 | Implemented |
IC0084 # 09 Y:2004 | 09 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $124,469 | $513 | Implemented |
IC0084 # 10 Y:2004 | 10 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $794 | $5,100 | Implemented |