Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
67
matching recommendationsNAICS | 331 | Primary Metal Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0457 # 04 Y:2018 | 04 | 2018 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $4,539 | $2,530 | Not Implemented |
AS0457 # 03 Y:2018 | 03 | 2018 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,791 | $19,647 | Not Implemented |
AS0457 # 02 Y:2018 | 02 | 2018 | USE SOLAR HEAT FOR HEAT | $7,441 | $1,961 | Not Implemented |
AS0457 # 01 Y:2018 | 01 | 2018 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,174 | $0 | Implemented |
SD0397 # 03 Y:2007 | 03 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,149 | $18,100 | Not Implemented |
SD0397 # 08 Y:2007 | 08 | 2007 | INSTALL SKYLIGHTS | $4,924 | $13,330 | Not Implemented |
SD0397 # 04 Y:2007 | 04 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $19,700 | $23,250 | Not Implemented |
SD0397 # 02 Y:2007 | 02 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $52,328 | $44,175 | Not Implemented |
SD0397 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $51,686 | $51,240 | Not Implemented |
SD0397 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,897 | $420 | Implemented |
SD0397 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,198 | $17,214 | Implemented |
SD0397 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,697 | $71,224 | Implemented |
SD0397 # 09 Y:2007 | 09 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,243 | $3,825 | Not Implemented |
AS0385 # 01 Y:2004 | 01 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $21,304 | $10,000 | Not Implemented |
AS0385 # 08 Y:2004 | 08 | 2004 | INSTALL / REPAIR INSULATION ON STEAM LINES | $339 | $150 | Not Implemented |
AS0385 # 02 Y:2004 | 02 | 2004 | ELIMINATE/REDUCE AN OPERATION | $151,757 | $37,000 | Not Implemented |
AS0385 # 03 Y:2004 | 03 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $59,563 | $24,322 | Not Implemented |
AS0385 # 04 Y:2004 | 04 | 2004 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $42,444 | $17,685 | Not Implemented |
AS0385 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $719 | $506 | Not Implemented |
AS0385 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $383 | $30 | Not Implemented |
AS0385 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,939 | $60 | Not Implemented |
AS0383 # 10 Y:2004 | 10 | 2004 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $577,735 | $9,735 | Not Implemented |
AS0383 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $2,878 | $1,350 | Not Implemented |
AS0383 # 03 Y:2004 | 03 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $16,320 | $40,000 | Not Implemented |
AS0383 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,498 | $120 | Not Implemented |