Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsNAICS | 331110 | Iron and Steel Mills and Ferroalloy Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0113 # 04 Y:2006 | 04 | 2006 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $87,860 | $500,000 | Not Implemented |
UU0113 # 03 Y:2006 | 03 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,530 | $20,000 | Not Implemented |
UU0113 # 02 Y:2006 | 02 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $173,190 | $46,250 | Not Implemented |
UU0113 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,620 | $180 | Not Implemented |
IC0123 # 02 Y:2006 | 02 | 2006 | ADJUST BURNERS FOR EFFICIENT OPERATION | $76,409 | $252,000 | Implemented |
IC0123 # 05 Y:2006 | 05 | 2006 | TREAT AND REUSE RINSE WATERS | $92,357 | $31,583 | Not Implemented |
IC0123 # 04 Y:2006 | 04 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $861,835 | $1,928,400 | Not Implemented |
IC0123 # 03 Y:2006 | 03 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,509,727 | $6,804,600 | Not Implemented |
IC0123 # 01 Y:2006 | 01 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,641,138 | $12,550,416 | Implemented |
WV0347 # 01 Y:2006 | 01 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $255,013 | $57,159 | Implemented |
WV0347 # 11 Y:2006 | 11 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $457 | $158 | Not Implemented |
WV0347 # 10 Y:2006 | 10 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $915 | $245 | Not Implemented |
WV0347 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,051 | $65 | Implemented |
WV0347 # 08 Y:2006 | 08 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $5,557 | $2,790 | Implemented |
WV0347 # 07 Y:2006 | 07 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,696 | $10,600 | Not Implemented |
WV0347 # 06 Y:2006 | 06 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,834 | $250 | Not Implemented |
WV0347 # 05 Y:2006 | 05 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $10,012 | $13,815 | Not Implemented |
WV0347 # 04 Y:2006 | 04 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $10,908 | $504 | Implemented |
WV0347 # 03 Y:2006 | 03 | 2006 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $11,796 | $1,000 | Implemented |
WV0347 # 02 Y:2006 | 02 | 2006 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $32,512 | $24,300 | Not Implemented |
LL0250 # 01 Y:2006 | 01 | 2006 | INSULATE BARE EQUIPMENT | $40,871 | $5,998 | Implemented |
LL0250 # 07 Y:2006 | 07 | 2006 | USE PHOTOCELL CONTROLS | $294 | $30 | Not Implemented |
LL0250 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $427 | $60 | Not Implemented |
LL0250 # 05 Y:2006 | 05 | 2006 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,580 | $596 | Not Implemented |
LL0250 # 04 Y:2006 | 04 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,081 | $60 | Not Implemented |