Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
999
matching recommendationsNAICS | 3312 | Steel Product Manufacturing from Purchased Steel |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0087 # 01 Y:2005 | 01 | 2005 | EXPAND OPERATIONS INTO UNUSED SPACE | $84,030 | $200,000 | Not Implemented |
UU0087 # 02 Y:2005 | 02 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $9,270 | $0 | Not Implemented |
UU0087 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,180 | $3,040 | Not Implemented |
UU0087 # 04 Y:2005 | 04 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,680 | $240 | Not Implemented |
UU0087 # 05 Y:2005 | 05 | 2005 | OPTIMIZE PLANT POWER FACTOR | $470 | $2,900 | Not Implemented |
UD0722 # 01 Y:2005 | 01 | 2005 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $113,700 | $454,800 | Not Implemented |
UD0722 # 02 Y:2005 | 02 | 2005 | INSTALL OCCUPANCY SENSORS | $6,570 | $21,200 | Not Implemented |
UD0722 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,334 | $192 | Implemented |
UD0722 # 04 Y:2005 | 04 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $2,776 | $1,448 | Implemented |
UD0722 # 05 Y:2005 | 05 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,734 | $9,650 | Implemented |
UD0722 # 06 Y:2005 | 06 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,730 | $0 | Not Implemented |
UD0722 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $104 | $102 | Implemented |
WV0317 # 01 Y:2005 | 01 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $28,323 | $0 | Not Implemented |
WV0317 # 02 Y:2005 | 02 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $23,795 | $50,000 | Not Implemented |
WV0317 # 03 Y:2005 | 03 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $13,415 | $5,677 | Not Implemented |
WV0317 # 04 Y:2005 | 04 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,217 | $490 | Implemented |
WV0317 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,041 | $60 | Implemented |
WV0317 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,531 | $680 | Implemented |
WV0317 # 07 Y:2005 | 07 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $4,392 | $855 | Implemented |
WV0317 # 08 Y:2005 | 08 | 2005 | INSULATE BARE EQUIPMENT | $4,285 | $128 | Implemented |
WV0317 # 09 Y:2005 | 09 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,086 | $2,295 | Implemented |
WV0317 # 10 Y:2005 | 10 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $1,435 | $2,075 | Not Implemented |
WV0317 # 11 Y:2005 | 11 | 2005 | INSTALL OCCUPANCY SENSORS | $1,219 | $2,680 | Implemented |
WV0317 # 12 Y:2005 | 12 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $761 | $205 | Implemented |
WV0317 # 13 Y:2005 | 13 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $400 | $240 | Implemented |