Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
26
matching recommendationsNAICS | 331210 | Iron and Steel Pipe and Tube Manufacturing from Purchased Steel |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0476 # 08 Y:2004 | 08 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $308 | $776 | Not Implemented |
WI0476 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,141 | $640 | Implemented |
WI0476 # 06 Y:2004 | 06 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,148 | $0 | Implemented |
WI0476 # 05 Y:2004 | 05 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,557 | $4,280 | Implemented |
WI0476 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $5,082 | $2,944 | Not Implemented |
WI0476 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,856 | $8,856 | Not Implemented |
WI0476 # 02 Y:2004 | 02 | 2004 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $15,807 | $21,000 | Not Implemented |
WI0476 # 01 Y:2004 | 01 | 2004 | BURN WASTE OIL FOR HEAT | $73,937 | $36,000 | Not Implemented |
LL0192 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $55,907 | $0 | Not Implemented |
LL0192 # 07 Y:2004 | 07 | 2004 | INSULATE BARE EQUIPMENT | $2,881 | $911 | Not Implemented |
LL0192 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $3,529 | $720 | Not Implemented |
LL0192 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,708 | $2,585 | Implemented |
LL0192 # 04 Y:2004 | 04 | 2004 | USE PHOTOCELL CONTROLS | $21,326 | $420 | Not Implemented |
LL0192 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $41,577 | $4,400 | Implemented |
LL0192 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $61,254 | $2,590 | Implemented |
LL0192 # 08 Y:2004 | 08 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,610 | $6,030 | Not Implemented |
WV0291 # 10 Y:2004 | 10 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $550 | $100 | Implemented |
WV0291 # 09 Y:2004 | 09 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $685 | $747 | Not Implemented |
WV0291 # 08 Y:2004 | 08 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,485 | $116 | Not Implemented |
WV0291 # 07 Y:2004 | 07 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,519 | $5,205 | Not Implemented |
WV0291 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $1,720 | $1,316 | Not Implemented |
WV0291 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,186 | $0 | Implemented |
WV0291 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,578 | $4,824 | Implemented |
WV0291 # 03 Y:2004 | 03 | 2004 | DEVELOP A REPAIR/REPLACE POLICY | $6,488 | $0 | Implemented |
WV0291 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,255 | $1,032 | Not Implemented |