Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
335
matching recommendationsNAICS | 331222 | Steel Wire Drawing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UC2309 # 01 Y:2023 | 01 | 2023 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,070 | $0 | Implemented |
UC2309 # 07 Y:2023 | 07 | 2023 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,846 | $33,462 | Not Implemented |
UC2309 # 06 Y:2023 | 06 | 2023 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $136 | $38 | Not Implemented |
UC2309 # 05 Y:2023 | 05 | 2023 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $155 | $494 | Not Implemented |
IC0228 # 01 Y:2019 | 01 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,679 | $14,948 | Implemented |
IC0228 # 02 Y:2019 | 02 | 2019 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $51,760 | $4,700 | Not Implemented |
IC0228 # 03 Y:2019 | 03 | 2019 | REPAIR OR REPLACE STEAM TRAPS | $9,605 | $2,359 | Implemented |
IC0228 # 04 Y:2019 | 04 | 2019 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,006 | $4,868 | Not Implemented |
IC0228 # 05 Y:2019 | 05 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $759 | $167 | Not Implemented |
UK1801 # 08 Y:2018 | 08 | 2018 | INSULATE BARE EQUIPMENT | $3,719 | $1,526 | Not Implemented |
UK1801 # 10 Y:2018 | 10 | 2018 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,756 | $5,475 | Not Implemented |
UK1801 # 06 Y:2018 | 06 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $860 | $1,250 | Implemented |
UK1801 # 05 Y:2018 | 05 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,263 | $2,190 | Implemented |
UK1801 # 11 Y:2018 | 11 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $0 | Not Implemented |
UK1801 # 04 Y:2018 | 04 | 2018 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $23,118 | $11,500 | Not Implemented |
UK1801 # 07 Y:2018 | 07 | 2018 | INSULATE BARE EQUIPMENT | $8,475 | $2,977 | Not Implemented |
UK1801 # 09 Y:2018 | 09 | 2018 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,865 | $5,895 | Not Implemented |
UK1801 # 03 Y:2018 | 03 | 2018 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $26,076 | $3,990 | Not Implemented |
UK1801 # 02 Y:2018 | 02 | 2018 | INSTALL OCCUPANCY SENSORS | $2,773 | $1,959 | Implemented |
UK1801 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,208 | $48,400 | Implemented |
OK0961 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,978 | $7,268 | Not Implemented |
OK0961 # 07 Y:2017 | 07 | 2017 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $216,378 | $7,000 | Not Implemented |
OK0961 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $831 | $3,220 | Not Implemented |
OK0961 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $80,050 | $185,484 | Not Implemented |
OK0961 # 01 Y:2017 | 01 | 2017 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,024 | $5,000 | Not Implemented |