Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

460

matching recommendations
Reset
NAICS 331318 Other Aluminum Rolling, Drawing, and Extruding
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0434 # 02 Y:2008 02 2008 ADD AREA LIGHTING SWITCHES $4,676 $1,417 Implemented
IA0434 # 03 Y:2008 03 2008 INSTALL OCCUPANCY SENSORS $1,439 $616 Implemented
IA0434 # 04 Y:2008 04 2008 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,457 $25 Not Implemented
IA0434 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,833 $596 Implemented
IA0434 # 06 Y:2008 06 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,490 $1,059 Implemented
IA0434 # 07 Y:2008 07 2008 INSULATE BARE EQUIPMENT $1,153 $600 Implemented
IA0434 # 08 Y:2008 08 2008 INSULATE BARE EQUIPMENT $764 $270 Not Implemented
IA0434 # 09 Y:2008 09 2008 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,060 $15,120 Implemented
IA0434 # 10 Y:2008 10 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $1,536 $280 Not Implemented
IA0434 # 11 Y:2008 11 2008 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $12,653 $7,425 Implemented
IA0434 # 12 Y:2008 12 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $19,902 $33,345 Not Implemented
UM0338 # 01 Y:2008 01 2008 RECOVER WASTE HEAT FROM EQUIPMENT $30,146 $38,350 Not Implemented
UM0338 # 02 Y:2008 02 2008 RECOVER WASTE HEAT FROM EQUIPMENT $16,908 $4,000 Not Implemented
UM0338 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,301 $19,680 Not Implemented
UM0338 # 04 Y:2008 04 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,640 $1,400 Not Implemented
UM0338 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,107 $900 Not Implemented
UM0338 # 06 Y:2008 06 2008 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,305 $4,480 Not Implemented
UM0338 # 07 Y:2008 07 2008 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES $257 $1,095 Not Implemented
UM0338 # 08 Y:2008 08 2008 INSTALL OCCUPANCY SENSORS $103 $270 Not Implemented
LE0271 # 01 Y:2008 01 2008 REPLACE DC EQUIPMENT WITH AC EQUIPMENT $94,198 $45,000 Implemented
LE0271 # 02 Y:2008 02 2008 INSTALL TIMERS AND/OR THERMOSTATS $35,042 $875 Not Implemented
LE0271 # 03 Y:2008 03 2008 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $27,263 $40,000 Not Implemented
LE0271 # 04 Y:2008 04 2008 USE RADIANT HEATER FOR SPOT HEATING $17,604 $3,900 Not Implemented
LE0271 # 05 Y:2008 05 2008 PREHEAT COMBUSTION AIR WITH WASTE HEAT $14,909 $30,000 Not Implemented
LE0271 # 06 Y:2008 06 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,337 $3,000 Implemented