Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
173
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0169 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $863 | $71 | Not Implemented |
IC0169 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $127 | $99 | Not Implemented |
IC0169 # 05 Y:2010 | 05 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $20,393 | $5,249 | Not Implemented |
IC0169 # 06 Y:2010 | 06 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,108 | $1,339 | Not Implemented |
IC0169 # 07 Y:2010 | 07 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $538 | $0 | Not Implemented |
IC0169 # 08 Y:2010 | 08 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $5,189 | $1,632 | Not Implemented |
IC0169 # 09 Y:2010 | 09 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,975 | $4,551 | Not Implemented |
IC0169 # 10 Y:2010 | 10 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $28,097 | $1,670 | Not Implemented |
IC0169 # 11 Y:2010 | 11 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $318 | $613 | Not Implemented |
IC0169 # 12 Y:2010 | 12 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $5,403 | $2,401 | Not Implemented |
IC0169 # 13 Y:2010 | 13 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,074 | $1,265 | Not Implemented |
IC0169 # 14 Y:2010 | 14 | 2010 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $124 | $600 | Not Implemented |
IC0169 # 15 Y:2010 | 15 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $245 | $0 | Not Implemented |
BD0351 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,834 | $48,839 | Not Implemented |
BD0351 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $2,088 | $2,250 | Not Implemented |
BD0351 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $412 | $425 | Not Implemented |
BD0351 # 04 Y:2008 | 04 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,907 | $1,500 | Not Implemented |
BD0351 # 05 Y:2008 | 05 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $62,988 | $47,700 | Not Implemented |
BD0351 # 06 Y:2008 | 06 | 2008 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $9,722 | $25,200 | Not Implemented |
BD0351 # 07 Y:2008 | 07 | 2008 | MODIFY STARTUP/SHUTDOWN TIMES | $84,567 | $63,000 | Not Implemented |
BD0346 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $84,447 | $2,972 | Implemented |
BD0346 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $1,472 | $676 | Not Implemented |
BD0346 # 03 Y:2008 | 03 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,548 | $4,569 | Not Implemented |
BD0346 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $893 | $1,366 | Not Implemented |
BD0346 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $48,385 | $10,001 | Implemented |