Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,045

matching recommendations
Reset
NAICS 3315 Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0428 # 05 Y:2008 05 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,344 $220 Implemented
IA0428 # 06 Y:2008 06 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,921 $511 Implemented
IA0428 # 07 Y:2008 07 2008 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $194 $3,086 Not Implemented
IA0428 # 08 Y:2008 08 2008 RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION $23,965 $2,500 Not Implemented
IA0428 # 09 Y:2008 09 2008 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $19,149 $10,000 Not Implemented
IA0428 # 10 Y:2008 10 2008 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $10,521 $10,000 Implemented
TT0026 # 01 Y:2008 01 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67,300 $63,800 Not Implemented
TT0026 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,980 $6,600 Not Implemented
TT0026 # 03 Y:2008 03 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,430 $3,640 Not Implemented
TT0026 # 04 Y:2008 04 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190 $590 Not Implemented
TT0026 # 05 Y:2008 05 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,119 $55,000 Not Implemented
TT0026 # 06 Y:2008 06 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,000 $4,900 Not Implemented
TT0026 # 07 Y:2008 07 2008 INSULATE BARE EQUIPMENT $25,000 $1,000 Not Implemented
TT0026 # 08 Y:2008 08 2008 OPTIMIZE PLANT POWER FACTOR $1,150 $6,000 Not Implemented
UF0413 # 01 Y:2008 01 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,814 $810 Implemented
UF0413 # 02 Y:2008 02 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $34,500 $54,000 Implemented
UF0413 # 03 Y:2008 03 2008 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,206 $16,270 Not Implemented
UF0413 # 04 Y:2008 04 2008 INSTALL OCCUPANCY SENSORS $1,150 $219 Implemented
UF0413 # 05 Y:2008 05 2008 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $14,800 $1,117 Implemented
UF0413 # 06 Y:2008 06 2008 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $13,321 $13,321 Implemented
UF0413 # 07 Y:2008 07 2008 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $12,742 $20,000 Not Implemented
UF0413 # 08 Y:2008 08 2008 INSTALL COMMON HEADER ON COMPRESSORS $871 $2,000 Implemented
UF0413 # 09 Y:2008 09 2008 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $151,840 $16,695 Not Implemented
UF0413 # 10 Y:2008 10 2008 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $9,571 $1,500 Not Implemented
UW0018 # 01 Y:2008 01 2008 UTILIZE JOB COSTING SOFTWARE $55,734 $72,000 Not Implemented