Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,045
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0553 # 03 Y:2004 | 03 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,980 | $9,830 | Not Implemented |
MA0553 # 04 Y:2004 | 04 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,977 | $12,543 | Implemented |
MA0553 # 05 Y:2004 | 05 | 2004 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $3,918 | $1,039 | Not Implemented |
MA0553 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,228 | $600 | Implemented |
MA0553 # 07 Y:2004 | 07 | 2004 | INSULATE FEEDWATER TANK | $910 | $550 | Implemented |
UD0696 # 01 Y:2004 | 01 | 2004 | AUTOMATE FINISHING PROCESS | $50,850 | $28,500 | Not Implemented |
UD0696 # 02 Y:2004 | 02 | 2004 | COVER OPEN TANKS | $19,683 | $2,870 | Not Implemented |
UD0696 # 03 Y:2004 | 03 | 2004 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $11,250 | $0 | Not Implemented |
UD0696 # 04 Y:2004 | 04 | 2004 | ELIMINATE/REDUCE AN OPERATION | $9,375 | $0 | Implemented |
UD0696 # 05 Y:2004 | 05 | 2004 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $9,026 | $2,405 | Not Implemented |
UD0696 # 06 Y:2004 | 06 | 2004 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $6,615 | $13,230 | Not Implemented |
UD0696 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,891 | $600 | Implemented |
UD0696 # 08 Y:2004 | 08 | 2004 | IMPROVE COMBUSTION CONTROL CAPABILITY | $1,617 | $0 | Implemented |
UD0696 # 09 Y:2004 | 09 | 2004 | DISCONNECT BALLASTS | $1,218 | $53 | Not Implemented |
UD0696 # 10 Y:2004 | 10 | 2004 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $845 | $0 | Implemented |
UD0696 # 11 Y:2004 | 11 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $631 | $486 | Implemented |
UD0696 # 12 Y:2004 | 12 | 2004 | REDUCE VENTILATION AIR | $1,416 | $0 | Not Implemented |
MA0549 # 01 Y:2004 | 01 | 2004 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $32,668 | $15,495 | Implemented |
MA0549 # 02 Y:2004 | 02 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,739 | $8,525 | Not Implemented |
MA0549 # 03 Y:2004 | 03 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $10,668 | $2,066 | Not Implemented |
MA0549 # 04 Y:2004 | 04 | 2004 | IMPROVE COMBUSTION CONTROL CAPABILITY | $8,653 | $16,100 | Implemented |
MA0549 # 05 Y:2004 | 05 | 2004 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $5,232 | $11,500 | Not Implemented |
MA0549 # 06 Y:2004 | 06 | 2004 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,412 | $0 | Implemented |
MA0549 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,794 | $315 | Implemented |
MA0549 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $1,041 | $896 | Implemented |