Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,045
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0160 # 05 Y:2003 | 05 | 2003 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $8,492 | $4,200 | Not Implemented |
SU0160 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,587 | $0 | Not Implemented |
SU0160 # 07 Y:2003 | 07 | 2003 | INSULATE BARE EQUIPMENT | $6,473 | $6,375 | Not Implemented |
SU0160 # 08 Y:2003 | 08 | 2003 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $4,145 | $12,781 | Not Implemented |
SU0160 # 09 Y:2003 | 09 | 2003 | INSULATE BARE EQUIPMENT | $1,997 | $3,315 | Not Implemented |
TA0051 # 01 Y:2003 | 01 | 2003 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $1,410,425 | $467,000 | Not Implemented |
TA0051 # 02 Y:2003 | 02 | 2003 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $53,166 | $17,450 | Implemented |
TA0051 # 03 Y:2003 | 03 | 2003 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $48,231 | $30,800 | Not Implemented |
TA0051 # 04 Y:2003 | 04 | 2003 | RECOVER AND REUSE COOLING WATER | $19,775 | $51,000 | Implemented |
TA0051 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,741 | $0 | Implemented |
NC0254 # 01 Y:2003 | 01 | 2003 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $639,636 | $10,000 | n/a |
NC0254 # 02 Y:2003 | 02 | 2003 | INSTALL SENSORS TO DETECT DEFECTS | $85,500 | $3,000 | Implemented |
NC0254 # 03 Y:2003 | 03 | 2003 | MODIFY STARTUP/SHUTDOWN TIMES | $1,342,708 | $10,000 | Implemented |
NC0254 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,930 | $20,000 | Not Implemented |
NC0254 # 05 Y:2003 | 05 | 2003 | COVER OPEN TANKS | $14,740 | $0 | Not Implemented |
NC0254 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $546 | $1,000 | Not Implemented |
NC0254 # 07 Y:2003 | 07 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,899 | $500 | Implemented |
NC0254 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,127 | $24,350 | Not Implemented |
NC0254 # 09 Y:2003 | 09 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $88,312 | $160,000 | Not Implemented |
NC0254 # 10 Y:2003 | 10 | 2003 | IMPROVE SPACE COMFORT CONDITIONING | $175,198 | $307,000 | Not Implemented |
UD0665 # 01 Y:2003 | 01 | 2003 | RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION | $380,000 | $38,587 | Not Implemented |
UD0665 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $74,995 | $40,000 | Not Implemented |
UD0665 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $14,021 | $1,545 | Not Implemented |
UD0665 # 04 Y:2003 | 04 | 2003 | COVER OPEN TANKS | $7,200 | $12,000 | Not Implemented |
UD0665 # 05 Y:2003 | 05 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,325 | $0 | Implemented |