Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,045
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0657 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,814 | $11,574 | Not Implemented |
OK0657 # 06 Y:2003 | 06 | 2003 | USE OPTIMUM THICKNESS INSULATION | $3,894 | $3,430 | Not Implemented |
OK0657 # 07 Y:2003 | 07 | 2003 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,378 | $7,500 | Not Implemented |
OK0657 # 08 Y:2003 | 08 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $11,624 | $11,750 | Implemented |
OK0657 # 09 Y:2003 | 09 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $624,000 | $10,149 | Not Implemented |
IA0312 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,964 | $779 | Not Implemented |
IA0312 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,291 | $25 | Not Implemented |
IA0312 # 03 Y:2003 | 03 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $58,932 | $136,000 | Not Implemented |
IA0312 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,061 | $0 | Implemented |
IA0312 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,976 | $8,950 | Implemented |
IA0312 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $677 | $2,261 | Implemented |
IA0312 # 07 Y:2003 | 07 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,748 | $1,356 | Implemented |
AS0345 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,950 | $30 | Implemented |
AS0345 # 02 Y:2003 | 02 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $294 | $30 | Not Implemented |
AS0345 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $519 | $3,755 | Implemented |
AS0345 # 04 Y:2003 | 04 | 2003 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,428 | $8,500 | Implemented |
AS0345 # 05 Y:2003 | 05 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $216 | $89 | Implemented |
AS0345 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $209 | $49 | Implemented |
AS0345 # 07 Y:2003 | 07 | 2003 | USE SYNTHETIC LUBRICANT | $420 | $3,231 | Not Implemented |
AS0345 # 08 Y:2003 | 08 | 2003 | INSTALL EQUIPMENT TO MOVE PRODUCT | $16,133 | $825 | Not Implemented |
AS0345 # 09 Y:2003 | 09 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $15,623 | $5,760 | Not Implemented |
AS0345 # 10 Y:2003 | 10 | 2003 | CLEAR AND RENT EXISTING SPACE | $11,984 | $9,060 | Not Implemented |
AS0345 # 11 Y:2003 | 11 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $910 | $960 | Not Implemented |
WI0437 # 01 Y:2003 | 01 | 2003 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $72,831 | $56,000 | Not Implemented |
WI0437 # 02 Y:2003 | 02 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $33,938 | $72,500 | Not Implemented |