IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

161

matching recommendations
Reset
NAICS 3315 Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0220 # 05 Y:2024 05 2024 INSTALL OCCUPANCY SENSORS $2,908 $2,206 n/a
WM0220 # 01 Y:2024 01 2024 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $134,386 $400,000 n/a
WM0220 # 02 Y:2024 02 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $29,665 $2,875 n/a
WM0220 # 04 Y:2024 04 2024 TURN OFF EQUIPMENT WHEN NOT IN USE $7,912 $0 n/a
WM0220 # 03 Y:2024 03 2024 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,427 $0 n/a
WM0219 # 03 Y:2024 03 2024 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,325 $6,594 n/a
WM0219 # 06 Y:2024 06 2024 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $918 $2,370 n/a
WM0219 # 05 Y:2024 05 2024 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,556 $0 n/a
WM0219 # 04 Y:2024 04 2024 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,229 $0 n/a
WM0219 # 01 Y:2024 01 2024 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $35,918 $200,000 n/a
WM0219 # 02 Y:2024 02 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,902 $3,000 n/a
WM0215 # 01 Y:2024 01 2024 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $39,768 $89,840 n/a
WM0215 # 02 Y:2024 02 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,470 $20,575 n/a
WM0215 # 03 Y:2024 03 2024 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $8,180 $0 n/a
WM0215 # 04 Y:2024 04 2024 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,912 $13,800 n/a
WM0215 # 05 Y:2024 05 2024 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,668 $1,750 n/a
WM0215 # 06 Y:2024 06 2024 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,360 $4,980 n/a
WM0207 # 04 Y:2024 04 2024 INSTALL OCCUPANCY SENSORS $3,129 $540 n/a
WM0207 # 03 Y:2024 03 2024 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,619 $4,084 n/a
WM0207 # 05 Y:2024 05 2024 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,225 $1,100 n/a
WM0207 # 01 Y:2024 01 2024 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $19,028 $12,825 n/a
WM0207 # 02 Y:2024 02 2024 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $16,759 $2,500 n/a
WM0180 # 04 Y:2022 04 2022 USE SYNTHETIC LUBRICANT $2,843 $4,510 Implemented
WM0180 # 07 Y:2022 07 2022 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $2,006 $0 Implemented
WM0180 # 05 Y:2022 05 2022 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $2,714 $0 Not Implemented