Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
133
matching recommendationsNAICS | 3315 | Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0242 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $849 | $1,005 | Implemented |
SU0242 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,530 | $32,632 | Implemented |
SU0242 # 06 Y:2006 | 06 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,265 | $524 | Implemented |
SU0242 # 05 Y:2006 | 05 | 2006 | INSULATE BARE EQUIPMENT | $12,811 | $4,204 | Implemented |
SU0242 # 04 Y:2006 | 04 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,673 | $0 | Implemented |
SU0242 # 03 Y:2006 | 03 | 2006 | USE SYNTHETIC LUBRICANT | $7,884 | $0 | Not Implemented |
UD0749 # 09 Y:2006 | 09 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $25,009 | $45,000 | Implemented |
UD0749 # 13 Y:2006 | 13 | 2006 | USE MINIMUM SAFE OVEN VENTILATION | $4,400 | $0 | Implemented |
UD0749 # 12 Y:2006 | 12 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,896 | $13,819 | Not Implemented |
UD0749 # 08 Y:2006 | 08 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $98,501 | $34,560 | Implemented |
UD0749 # 04 Y:2006 | 04 | 2006 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $151,097 | $0 | Not Implemented |
UD0749 # 03 Y:2006 | 03 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $211,000 | $7,200 | Implemented |
UD0749 # 01 Y:2006 | 01 | 2006 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $973,467 | $1,500,000 | Not Implemented |
UD0749 # 02 Y:2006 | 02 | 2006 | REDUCE VENTILATION AIR | $359,088 | $0 | Not Implemented |
UD0749 # 10 Y:2006 | 10 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $22,598 | $20,000 | Implemented |
UD0749 # 11 Y:2006 | 11 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,254 | $0 | Implemented |
UD0749 # 05 Y:2006 | 05 | 2006 | INSULATE BARE EQUIPMENT | $128,436 | $44,181 | Implemented |
UD0749 # 06 Y:2006 | 06 | 2006 | MINIMIZE NON-ESSENTIAL MATERIAL IN HEAT TREATMENT PROCESS | $127,000 | $20,000 | Not Implemented |
UD0749 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $111,197 | $15,000 | Not Implemented |
UM0307 # 13 Y:2006 | 13 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $754 | $75 | Implemented |
UM0307 # 12 Y:2006 | 12 | 2006 | INSULATE BARE EQUIPMENT | $3,085 | $0 | Implemented |
UM0307 # 11 Y:2006 | 11 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,358 | $2,100 | Not Implemented |
UM0307 # 10 Y:2006 | 10 | 2006 | INSULATE BARE EQUIPMENT | $3,606 | $1,191 | Implemented |
UM0307 # 08 Y:2006 | 08 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,428 | $2,000 | Implemented |
UM0307 # 07 Y:2006 | 07 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,914 | $5,000 | Not Implemented |