Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
638
matching recommendationsNAICS | 331511 | Iron Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0329 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $74,880 | $39,375 | Implemented |
UM0329 # 04 Y:2007 | 04 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $40,784 | $265,000 | Not Implemented |
UM0329 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,455 | $6,300 | Implemented |
UA0004 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,724 | $34,990 | Not Implemented |
UA0004 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,674 | $974 | Not Implemented |
UA0004 # 03 Y:2007 | 03 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,587 | $0 | Implemented |
UA0004 # 04 Y:2007 | 04 | 2007 | INSTALL TIMERS AND/OR THERMOSTATS | $435 | $1,534 | Not Implemented |
UA0004 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,488 | $1,400 | Not Implemented |
UA0004 # 06 Y:2007 | 06 | 2007 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $2,169 | $230 | Implemented |
UA0004 # 07 Y:2007 | 07 | 2007 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $5,479 | $400 | Not Implemented |
UA0004 # 08 Y:2007 | 08 | 2007 | UPGRADE OBSOLETE EQUIPMENT | $47,141 | $67,908 | Not Implemented |
UA0004 # 09 Y:2007 | 09 | 2007 | USE OPTIMUM THICKNESS INSULATION | $17,420 | $1,926 | Not Implemented |
UA0004 # 10 Y:2007 | 10 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,180 | $2,897 | Not Implemented |
UA0004 # 11 Y:2007 | 11 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,282 | $0 | Not Implemented |
IC0128 # 01 Y:2007 | 01 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,654 | $1,710 | Implemented |
IC0128 # 02 Y:2007 | 02 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,523 | $6,000 | Not Implemented |
IC0128 # 03 Y:2007 | 03 | 2007 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $25,162 | $21,540 | Implemented |
IC0128 # 04 Y:2007 | 04 | 2007 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $103,122 | $9,600 | Not Implemented |
IC0128 # 05 Y:2007 | 05 | 2007 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $44,610 | $0 | Not Implemented |
IC0128 # 06 Y:2007 | 06 | 2007 | IMPROVE SPACE COMFORT CONDITIONING | $11,886 | $10,408 | Not Implemented |
IC0128 # 07 Y:2007 | 07 | 2007 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $21,900 | $5,883 | Implemented |
IC0128 # 08 Y:2007 | 08 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,566 | $11,407 | Implemented |
IC0128 # 09 Y:2007 | 09 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $249 | $260 | Implemented |
IC0128 # 10 Y:2007 | 10 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,851 | $30,665 | Implemented |
LE0251 # 01 Y:2007 | 01 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $35,204 | $3,330 | Implemented |