Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

444

matching recommendations
Reset
NAICS 33152 Nonferrous Metal Foundries
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0349 # 03 Y:2006 03 2006 RECOVER WASTE HEAT FROM EQUIPMENT $14,527 $640 Implemented
WV0349 # 04 Y:2006 04 2006 REDUCE VENTILATION AIR $13,672 $10,295 Implemented
WV0349 # 07 Y:2006 07 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $5,242 $400 Implemented
WV0349 # 08 Y:2006 08 2006 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $4,291 $1,000 Implemented
WV0349 # 09 Y:2006 09 2006 INSULATE BARE EQUIPMENT $3,740 $1,318 Implemented
WV0349 # 11 Y:2006 11 2006 DEVELOP A REPAIR/REPLACE POLICY $1,998 $512 Implemented
WV0349 # 12 Y:2006 12 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $375 $200 Implemented
UD0742 # 02 Y:2006 02 2006 UPGRADE CONTROLS ON COMPRESSORS $198,228 $100,000 Implemented
UD0742 # 04 Y:2006 04 2006 REDESIGN PROCESS $174,377 $0 Implemented
UD0742 # 09 Y:2006 09 2006 REDUCE COMBUSTION AIR FLOW TO OPTIMUM $55,855 $10,000 Implemented
UD0742 # 11 Y:2006 11 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $26,660 $122,500 Implemented
UD0742 # 12 Y:2006 12 2006 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $19,230 $0 Implemented
UD0742 # 14 Y:2006 14 2006 UPGRADE CONTROLS ON COMPRESSORS $17,949 $0 Implemented
UD0742 # 16 Y:2006 16 2006 REDUCE WATER USE WITH COUNTER CURRENT RINSING $7,083 $0 Implemented
UD0742 # 18 Y:2006 18 2006 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,020 $0 Implemented
UD0742 # 19 Y:2006 19 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $874 $867 Implemented
WI0519 # 02 Y:2006 02 2006 IMPROVE SPACE COMFORT CONDITIONING $30,000 $1,800 Implemented
WI0519 # 04 Y:2006 04 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,299 $0 Implemented
WI0519 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,324 $1,920 Implemented
SU0237 # 03 Y:2006 03 2006 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,173 $0 Implemented
SU0237 # 04 Y:2006 04 2006 USE SYNTHETIC LUBRICANT $606 $0 Implemented
SU0237 # 06 Y:2006 06 2006 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,115 $219 Implemented
SU0237 # 07 Y:2006 07 2006 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $660 $220 Implemented
SU0237 # 08 Y:2006 08 2006 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,224 $7,782 Implemented
MA0604 # 02 Y:2006 02 2006 INSULATE BARE EQUIPMENT $20,912 $14,335 Implemented