Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
998
matching recommendationsNAICS | 33152 | Nonferrous Metal Foundries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0346 # 02 Y:2008 | 02 | 2008 | INSTALL OCCUPANCY SENSORS | $1,472 | $676 | Not Implemented |
BD0346 # 03 Y:2008 | 03 | 2008 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,548 | $4,569 | Not Implemented |
BD0346 # 04 Y:2008 | 04 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $893 | $1,366 | Not Implemented |
BD0346 # 05 Y:2008 | 05 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $48,385 | $10,001 | Implemented |
BD0346 # 06 Y:2008 | 06 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $833 | $501 | Implemented |
BD0346 # 07 Y:2008 | 07 | 2008 | REPLACE BOILER | $37,675 | $65,001 | Not Implemented |
BD0346 # 08 Y:2008 | 08 | 2008 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $4,096 | $1,251 | Not Implemented |
BD0346 # 09 Y:2008 | 09 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $19,119 | $14,001 | Not Implemented |
IA0423 # 01 Y:2008 | 01 | 2008 | REPAIR AND ELIMINATE STEAM LEAKS | $2,458 | $617 | Implemented |
IA0423 # 02 Y:2008 | 02 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $443 | $25 | Implemented |
IA0423 # 03 Y:2008 | 03 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $1,639 | $150 | Not Implemented |
IA0423 # 04 Y:2008 | 04 | 2008 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $516 | $86 | Implemented |
IA0423 # 05 Y:2008 | 05 | 2008 | INSTALL OCCUPANCY SENSORS | $697 | $1,001 | Not Implemented |
IA0423 # 06 Y:2008 | 06 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,415 | $18,345 | Not Implemented |
IA0422 # 01 Y:2008 | 01 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,946 | $660 | Implemented |
IA0422 # 02 Y:2008 | 02 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,525 | $15 | Implemented |
IA0422 # 03 Y:2008 | 03 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,191 | $300 | Implemented |
IA0422 # 04 Y:2008 | 04 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,842 | $2,300 | Not Implemented |
IA0422 # 05 Y:2008 | 05 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,261 | $305 | Implemented |
IA0422 # 06 Y:2008 | 06 | 2008 | INSULATE BARE EQUIPMENT | $6,865 | $6,165 | Implemented |
IA0422 # 07 Y:2008 | 07 | 2008 | RELOCATE OVEN / FURNACE TO MORE EFFICIENT LOCATION | $1,379 | $350 | Not Implemented |
IA0422 # 08 Y:2008 | 08 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,350 | $0 | Implemented |
IA0422 # 09 Y:2008 | 09 | 2008 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $474 | $143 | Implemented |
IA0422 # 10 Y:2008 | 10 | 2008 | INSTALL OCCUPANCY SENSORS | $1,310 | $1,155 | Not Implemented |
IA0422 # 11 Y:2008 | 11 | 2008 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $664 | $250 | Implemented |