Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsNAICS | 331524 | Aluminum Foundries (except Die-Casting) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0266 # 10 Y:2003 | 10 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,326 | $0 | Implemented |
WV0266 # 11 Y:2003 | 11 | 2003 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $142,002 | $980,000 | Not Implemented |
WV0266 # 12 Y:2003 | 12 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,000 | $2,550 | Implemented |
WV0266 # 13 Y:2003 | 13 | 2003 | INSTALL SPECTRAL REFLECTORS / DELAMP | $994 | $1,240 | Not Implemented |
WV0266 # 14 Y:2003 | 14 | 2003 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $39,573 | $0 | Implemented |
SU0160 # 02 Y:2003 | 02 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $158,477 | $3,600 | Not Implemented |
SU0160 # 01 Y:2003 | 01 | 2003 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $446,941 | $142,000 | Not Implemented |
SU0160 # 03 Y:2003 | 03 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,336,834 | $875,536 | Implemented |
SU0160 # 04 Y:2003 | 04 | 2003 | INSULATE BARE EQUIPMENT | $16,605 | $34,047 | Not Implemented |
SU0160 # 05 Y:2003 | 05 | 2003 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $8,492 | $4,200 | Not Implemented |
SU0160 # 06 Y:2003 | 06 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,587 | $0 | Not Implemented |
SU0160 # 07 Y:2003 | 07 | 2003 | INSULATE BARE EQUIPMENT | $6,473 | $6,375 | Not Implemented |
SU0160 # 08 Y:2003 | 08 | 2003 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $4,145 | $12,781 | Not Implemented |
SU0160 # 09 Y:2003 | 09 | 2003 | INSULATE BARE EQUIPMENT | $1,997 | $3,315 | Not Implemented |
UD0665 # 04 Y:2003 | 04 | 2003 | COVER OPEN TANKS | $7,200 | $12,000 | Not Implemented |
UD0665 # 03 Y:2003 | 03 | 2003 | INSULATE BARE EQUIPMENT | $14,021 | $1,545 | Not Implemented |
UD0665 # 05 Y:2003 | 05 | 2003 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,325 | $0 | Implemented |
UD0665 # 06 Y:2003 | 06 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,561 | $8,112 | Implemented |
UD0665 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,363 | $6,762 | Not Implemented |
UD0665 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,130 | $1,000 | Not Implemented |
UD0665 # 09 Y:2003 | 09 | 2003 | DISCONNECT BALLASTS | $790 | $45 | Implemented |
UD0665 # 10 Y:2003 | 10 | 2003 | COVER OPEN TANKS | $256 | $400 | Implemented |
UD0665 # 02 Y:2003 | 02 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $74,995 | $40,000 | Not Implemented |
UD0665 # 01 Y:2003 | 01 | 2003 | $380,000 | $38,587 | Not Implemented |