Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
10,517
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0729 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,514 | $0 | Not Implemented |
UD0729 # 05 Y:2005 | 05 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $19,115 | $0 | Implemented |
UD0729 # 06 Y:2005 | 06 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $11,374 | $1,725 | Implemented |
UD0729 # 07 Y:2005 | 07 | 2005 | DISCONNECT BALLASTS | $8,190 | $2,250 | Implemented |
UD0729 # 08 Y:2005 | 08 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,187 | $4,650 | Not Implemented |
UD0729 # 09 Y:2005 | 09 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,422 | $0 | Not Implemented |
UD0729 # 10 Y:2005 | 10 | 2005 | INSULATE BARE EQUIPMENT | $487 | $0 | Implemented |
WV0326 # 01 Y:2005 | 01 | 2005 | INSULATE BARE EQUIPMENT | $6,011 | $1,797 | Implemented |
WV0326 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,897 | $14,339 | Implemented |
WV0326 # 03 Y:2005 | 03 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,386 | $1,840 | Implemented |
WV0326 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,621 | $2,722 | Not Implemented |
WV0326 # 05 Y:2005 | 05 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,818 | $1,000 | Implemented |
WV0326 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,047 | $3,517 | Not Implemented |
WV0326 # 07 Y:2005 | 07 | 2005 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $780 | $1,076 | Implemented |
WV0326 # 08 Y:2005 | 08 | 2005 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $652 | $367 | Implemented |
WV0326 # 09 Y:2005 | 09 | 2005 | USE SYNTHETIC LUBRICANT | $577 | $17 | Implemented |
WV0326 # 10 Y:2005 | 10 | 2005 | DEVELOP A REPAIR/REPLACE POLICY | $459 | $54 | Implemented |
WV0326 # 11 Y:2005 | 11 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $388 | $140 | Not Implemented |
WV0326 # 12 Y:2005 | 12 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $295 | $180 | Implemented |
MI0117 # 01 Y:2005 | 01 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,898 | $1,350 | Implemented |
MI0117 # 02 Y:2005 | 02 | 2005 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,463 | $11,400 | Implemented |
MI0117 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,012 | $906 | Implemented |
MI0117 # 04 Y:2005 | 04 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,621 | $56 | Not Implemented |
MI0117 # 05 Y:2005 | 05 | 2005 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,044 | $5,024 | Not Implemented |
LE0220 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $13,454 | $18,500 | Not Implemented |