Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,034
matching recommendationsNAICS | 332 | Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0459 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,020 | $500 | Implemented |
AM0459 # 04 Y:2004 | 04 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,680 | $320 | Implemented |
AM0459 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $1,060 | $430 | Not Implemented |
AM0459 # 06 Y:2004 | 06 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $395 | $30 | Implemented |
AM0459 # 07 Y:2004 | 07 | 2004 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $130 | $20 | Implemented |
AM0459 # 08 Y:2004 | 08 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $13,700 | $1,350 | Implemented |
AM0459 # 09 Y:2004 | 09 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $770 | $470 | Implemented |
AM0457 # 01 Y:2004 | 01 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,750 | $21 | Implemented |
AM0457 # 02 Y:2004 | 02 | 2004 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,360 | $4,370 | Implemented |
AM0457 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,270 | $120 | Implemented |
AM0457 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $790 | $500 | Implemented |
AM0457 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $265 | $130 | Implemented |
AM0457 # 06 Y:2004 | 06 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $230 | $0 | Implemented |
AM0457 # 07 Y:2004 | 07 | 2004 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $84,400 | $8,800 | Not Implemented |
AM0457 # 08 Y:2004 | 08 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,910 | $880 | Implemented |
AM0451 # 01 Y:2004 | 01 | 2004 | OPTIMIZE PLANT POWER FACTOR | $13,040 | $12,960 | Not Implemented |
AM0451 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,160 | $500 | Implemented |
AM0451 # 03 Y:2004 | 03 | 2004 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,300 | $15,770 | n/a |
AM0451 # 04 Y:2004 | 04 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,830 | $0 | Implemented |
AM0451 # 05 Y:2004 | 05 | 2004 | REUSE RAGS UNTIL COMPLETELY SOILED | $1,790 | $1,910 | Implemented |
AM0451 # 06 Y:2004 | 06 | 2004 | COVER OPEN TANKS | $940 | $500 | Not Implemented |
AM0451 # 07 Y:2004 | 07 | 2004 | COVER OPEN TANKS | $805 | $500 | Not Implemented |
AM0451 # 08 Y:2004 | 08 | 2004 | PAY BILLS ON TIME TO AVOID LATE FEES | $200 | $0 | Implemented |
AM0448 # 01 Y:2003 | 01 | 2003 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $1,266,100 | $805,000 | Implemented |
AM0448 # 02 Y:2003 | 02 | 2003 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $24,300 | $5,730 | Implemented |