Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,062

matching recommendations
Reset
NAICS 3321 Forging and Stamping
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0689 # 10 Y:2004 10 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $2,425 $2,540 Not Implemented
UD0689 # 11 Y:2004 11 2004 UPGRADE CONTROLS ON COMPRESSORS $2,285 $0 Implemented
UD0689 # 12 Y:2004 12 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,715 $640 Implemented
UD0689 # 13 Y:2004 13 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,680 $0 Implemented
UD0689 # 14 Y:2004 14 2004 USE PHOTOCELL CONTROLS $1,210 $2,040 Not Implemented
UD0689 # 15 Y:2004 15 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,012 $1,566 Not Implemented
UD0689 # 16 Y:2004 16 2004 USE RADIANT HEATER FOR SPOT HEATING $911 $1,436 Not Implemented
UD0689 # 17 Y:2004 17 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $175 $58 Implemented
UD0689 # 18 Y:2004 18 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $155 $0 Implemented
UD0688 # 01 Y:2004 01 2004 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT $525,435 $1,000,000 Not Implemented
UD0688 # 02 Y:2004 02 2004 USE OPTIMUM TEMPERATURE $143,925 $500,000 Implemented
UD0688 # 03 Y:2004 03 2004 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $31,450 $7,250 Implemented
UD0688 # 04 Y:2004 04 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,315 $40,500 Not Implemented
UD0688 # 05 Y:2004 05 2004 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $12,457 $31,250 Implemented
UD0688 # 06 Y:2004 06 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $11,875 $7,400 Not Implemented
UD0688 # 07 Y:2004 07 2004 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $10,025 $30,885 Not Implemented
UD0688 # 08 Y:2004 08 2004 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $10,000 $1,040 Implemented
UD0688 # 09 Y:2004 09 2004 TURN OFF EQUIPMENT WHEN NOT IN USE $5,165 $6,370 Implemented
UD0688 # 10 Y:2004 10 2004 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,750 $1,005 Not Implemented
UD0688 # 11 Y:2004 11 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,745 $470 Implemented
UD0688 # 12 Y:2004 12 2004 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $3,670 $6,000 Not Implemented
UD0688 # 13 Y:2004 13 2004 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $2,840 $0 Implemented
UD0688 # 14 Y:2004 14 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,460 $0 Implemented
UD0688 # 15 Y:2004 15 2004 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,100 $1,500 Not Implemented
UD0688 # 16 Y:2004 16 2004 COVER OPEN TANKS $2,010 $2,440 Not Implemented