Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,062
matching recommendationsNAICS | 33211 | Forging and Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0004 # 01 Y:2012 | 01 | 2012 | INSULATE BARE EQUIPMENT | $798 | $433 | Implemented |
WM0004 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,871 | $100,000 | Not Implemented |
WM0004 # 03 Y:2012 | 03 | 2012 | COVER OPEN TANKS | $1,078 | $700 | Not Implemented |
WM0004 # 04 Y:2012 | 04 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,511 | $1,000 | Implemented |
WM0004 # 05 Y:2012 | 05 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,175 | $39,950 | Implemented |
WM0004 # 06 Y:2012 | 06 | 2012 | USE PHOTOCELL CONTROLS | $3,555 | $4,750 | Not Implemented |
WM0004 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,280 | $750 | Implemented |
WM0004 # 08 Y:2012 | 08 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $273 | $660 | Implemented |
MZ0096 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $57,095 | $67,348 | Implemented |
MZ0096 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $28,732 | $29,201 | Implemented |
MZ0096 # 03 Y:2012 | 03 | 2012 | COMBINE UTILITY METERS | $19,635 | $10,000 | Not Implemented |
MZ0096 # 04 Y:2012 | 04 | 2012 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $15,197 | $16,000 | Not Implemented |
MZ0096 # 05 Y:2012 | 05 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $11,800 | $22,100 | Implemented |
MZ0096 # 06 Y:2012 | 06 | 2012 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $6,087 | $3,554 | Not Implemented |
MZ0096 # 07 Y:2012 | 07 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,395 | $5,400 | Implemented |
MZ0096 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $896 | $221 | Implemented |
MZ0096 # 09 Y:2012 | 09 | 2012 | USE PHOTOCELL CONTROLS | $507 | $560 | Implemented |
MZ0096 # 10 Y:2012 | 10 | 2012 | INSTALL OCCUPANCY SENSORS | $455 | $480 | Implemented |
MZ0096 # 11 Y:2012 | 11 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $467 | $480 | Implemented |
UD0858 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,297 | $12,425 | Not Implemented |
UD0858 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,138 | $3,850 | Not Implemented |
UD0858 # 03 Y:2012 | 03 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,006 | $500 | Implemented |
UD0858 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $1,000 | Implemented |
UD0858 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $399 | $300 | Not Implemented |
UD0858 # 06 Y:2012 | 06 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $409 | $360 | Not Implemented |