Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,062
matching recommendationsNAICS | 33211 | Forging and Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0190 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,423 | $2,049 | n/a |
IC0190 # 07 Y:2011 | 07 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $6,206 | $11,658 | n/a |
IC0190 # 08 Y:2011 | 08 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $26,660 | $128,000 | n/a |
IC0190 # 09 Y:2011 | 09 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,770 | $140 | n/a |
IC0190 # 10 Y:2011 | 10 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $289 | $0 | n/a |
UM0391 # 01 Y:2011 | 01 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $38,198 | $7,100 | Not Implemented |
UM0391 # 02 Y:2011 | 02 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $3,190 | $2,000 | Not Implemented |
UM0391 # 03 Y:2011 | 03 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $30,887 | $50,000 | Not Implemented |
UM0391 # 04 Y:2011 | 04 | 2011 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $4,244 | $1,000 | Implemented |
TT0064 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,600 | $2,500 | Implemented |
TT0064 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,400 | $26,700 | Implemented |
TT0064 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $957 | $4,000 | Implemented |
TT0064 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $414 | $3,200 | Implemented |
TT0064 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,844 | $29,100 | Implemented |
TT0064 # 06 Y:2011 | 06 | 2011 | OPTIMIZE PLANT POWER FACTOR | $7,300 | $8,500 | Implemented |
TT0064 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $37,600 | $5,500 | Implemented |
TT0064 # 08 Y:2011 | 08 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,800 | $5,000 | Implemented |
UA3011 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,307 | $26,402 | Not Implemented |
UA3011 # 02 Y:2011 | 02 | 2011 | USE PHOTOCELL CONTROLS | $575 | $225 | Implemented |
UA3011 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,842 | $5,000 | Implemented |
UA3011 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,087 | $640 | Not Implemented |
UA3011 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,304 | $1,800 | Not Implemented |
UA3011 # 06 Y:2011 | 06 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $515 | $1,030 | Implemented |
UA3011 # 07 Y:2011 | 07 | 2011 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,440 | $4,586 | Not Implemented |
UA3011 # 08 Y:2011 | 08 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,373 | $320 | Not Implemented |