Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,097
matching recommendationsNAICS | 33211 | Forging and Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0560 # 06 Y:2023 | 06 | 2023 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $112 | $414 | Not Implemented |
AS0560 # 04 Y:2023 | 04 | 2023 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $5,025 | $75,360 | Implemented |
AS0560 # 03 Y:2023 | 03 | 2023 | UPGRADE OBSOLETE EQUIPMENT | $21,635 | $819,000 | Implemented |
AS0560 # 02 Y:2023 | 02 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $51,728 | $659,540 | Implemented |
AS0560 # 01 Y:2023 | 01 | 2023 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $701,165 | $7,692,249 | Not Implemented |
WV0640 # 12 Y:2023 | 12 | 2023 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $66 | $178 | Implemented |
WV0640 # 11 Y:2023 | 11 | 2023 | INSULATE BARE EQUIPMENT | $930 | $135 | Implemented |
WV0640 # 10 Y:2023 | 10 | 2023 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,582 | $5,558 | Implemented |
WV0640 # 09 Y:2023 | 09 | 2023 | UPGRADE CONTROLS ON COMPRESSORS | $2,907 | $11,135 | Not Implemented |
WV0640 # 08 Y:2023 | 08 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,011 | $596 | Implemented |
WV0640 # 07 Y:2023 | 07 | 2023 | DEVELOP A REPAIR/REPLACE POLICY | $3,201 | $1,563 | Implemented |
WV0640 # 06 Y:2023 | 06 | 2023 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,905 | $1,500 | Implemented |
WV0640 # 05 Y:2023 | 05 | 2023 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,135 | $10,165 | Implemented |
WV0640 # 04 Y:2023 | 04 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,002 | $9,194 | Implemented |
WV0640 # 03 Y:2023 | 03 | 2023 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $43,563 | $209,750 | Not Implemented |
WV0640 # 02 Y:2023 | 02 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $43,670 | $212,780 | Not Implemented |
WV0640 # 01 Y:2023 | 01 | 2023 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $216,485 | $812,825 | Not Implemented |
IP0169 # 15 Y:2023 | 15 | 2023 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $10,836 | $47,613 | Not Implemented |
IP0169 # 14 Y:2023 | 14 | 2023 | DISCONNECT BALLASTS | $7 | $20 | Implemented |
IP0169 # 13 Y:2023 | 13 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,020 | $7,379 | Implemented |
IP0169 # 12 Y:2023 | 12 | 2023 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,942 | $9,196 | Not Implemented |
IP0169 # 11 Y:2023 | 11 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,267 | $5,079 | Implemented |
IP0169 # 10 Y:2023 | 10 | 2023 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $10,071 | $15,432 | Implemented |
IP0169 # 09 Y:2023 | 09 | 2023 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $786 | $679 | Implemented |
IP0169 # 08 Y:2023 | 08 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,155 | $837 | Implemented |