Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,062
matching recommendationsNAICS | 33211 | Forging and Stamping |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0537 # 05 Y:2023 | 05 | 2023 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,193 | $7,500 | Not Implemented |
LE0537 # 04 Y:2023 | 04 | 2023 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $6,501 | $7,500 | Not Implemented |
LE0537 # 03 Y:2023 | 03 | 2023 | INSTALL TIMERS AND/OR THERMOSTATS | $825 | $570 | Implemented |
LE0537 # 02 Y:2023 | 02 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,776 | $15,000 | Not Implemented |
LE0537 # 01 Y:2023 | 01 | 2023 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $167,234 | $0 | Implemented |
MU0008 # 05 Y:2022 | 05 | 2022 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $11,502 | $0 | Not Implemented |
MU0008 # 04 Y:2022 | 04 | 2022 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $2,790 | $580 | Not Implemented |
MU0008 # 03 Y:2022 | 03 | 2022 | USE OPTIMUM TEMPERATURE | $168 | $0 | Implemented |
MU0008 # 02 Y:2022 | 02 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,317 | $2,520 | Implemented |
MU0008 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $263 | $210 | Not Implemented |
MU0003 # 08 Y:2022 | 08 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $326 | $0 | Not Implemented |
MU0003 # 07 Y:2022 | 07 | 2022 | TURN OFF EQUIPMENT WHEN NOT IN USE | $104 | $0 | Not Implemented |
MU0003 # 06 Y:2022 | 06 | 2022 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,452 | $1,180 | Not Implemented |
MU0003 # 05 Y:2022 | 05 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,005 | $4,005 | Not Implemented |
MU0003 # 04 Y:2022 | 04 | 2022 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $421 | $0 | Not Implemented |
MU0003 # 03 Y:2022 | 03 | 2022 | PAY BILLS ON TIME TO AVOID LATE FEES | $2,120 | $0 | Not Implemented |
MU0003 # 02 Y:2022 | 02 | 2022 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,354 | $6,000 | Not Implemented |
MU0003 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $152 | $480 | Not Implemented |
UL2205 # 05 Y:2022 | 05 | 2022 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,986 | $0 | Implemented |
UL2205 # 04 Y:2022 | 04 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $427,303 | $4,465,290 | Not Implemented |
UL2205 # 03 Y:2022 | 03 | 2022 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $80,954 | $524,616 | Not Implemented |
UL2205 # 02 Y:2022 | 02 | 2022 | OPTIMIZE PLANT POWER FACTOR | $83,199 | $100,000 | Not Implemented |
UL2205 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,490 | $11,516 | Implemented |
UL2204 # 08 Y:2022 | 08 | 2022 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $84,924 | $750,000 | Not Implemented |
UL2204 # 07 Y:2022 | 07 | 2022 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $299 | $1,156 | Not Implemented |