matching recommendationsNAICS | 33221 | Cutlery and Handtool Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0677 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $4,053 | $200 | Not Implemented |
MA0677 # 03 Y:2011 | 03 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $1,514 | $5,967 | Implemented |
MA0677 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,225 | $200 | Implemented |
MA0677 # 05 Y:2011 | 05 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $912 | $8,300 | Not Implemented |
MA0677 # 06 Y:2011 | 06 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $362 | $500 | Implemented |
MA0677 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $107 | $100 | Implemented |
MA0677 # 01 Y:2011 | 01 | 2011 | REDUCE VENTILATION AIR | $9,048 | $2,585 | Implemented |
WV0431 # 08 Y:2011 | 08 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,027 | $1,560 | Implemented |
WV0431 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $2,808 | $408 | Implemented |
WV0431 # 06 Y:2011 | 06 | 2011 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,020 | $0 | Not Implemented |
WV0431 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $6,207 | $1,076 | Implemented |
WV0431 # 04 Y:2011 | 04 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $7,105 | $1,850 | Implemented |
WV0431 # 03 Y:2011 | 03 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,355 | $11,500 | Not Implemented |
WV0431 # 02 Y:2011 | 02 | 2011 | USE OPTIMUM THICKNESS INSULATION | $29,707 | $75,000 | Not Implemented |
WV0431 # 01 Y:2011 | 01 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $135,254 | $682,000 | Implemented |
MA0673 # 08 Y:2011 | 08 | 2011 | INSULATE BARE EQUIPMENT | $386 | $450 | Not Implemented |
MA0673 # 07 Y:2011 | 07 | 2011 | INSTALL OCCUPANCY SENSORS | $743 | $1,800 | Not Implemented |
MA0673 # 06 Y:2011 | 06 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,078 | $200 | Implemented |
MA0673 # 05 Y:2011 | 05 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,432 | $6,475 | Not Implemented |
MA0673 # 04 Y:2011 | 04 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,179 | $8,435 | Not Implemented |
MA0673 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,772 | $540 | Implemented |
MA0673 # 02 Y:2011 | 02 | 2011 | USE MINIMUM SAFE OVEN VENTILATION | $3,752 | $490 | Not Implemented |
MA0673 # 01 Y:2011 | 01 | 2011 | INSULATE BARE EQUIPMENT | $4,145 | $1,370 | Implemented |