Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,171
matching recommendationsNAICS | 3323 | Architectural and Structural Metals Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS2201 # 04 Y:2022 | 04 | 2022 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $121 | $49 | Implemented |
LS2201 # 05 Y:2022 | 05 | 2022 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $482 | $240 | Not Implemented |
LS2201 # 06 Y:2022 | 06 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $99 | $50 | Not Implemented |
LS2201 # 07 Y:2022 | 07 | 2022 | USE TANKS WITH A CONICAL BOTTOM OUTLET SECTION TO REDUCE WASTE ASSOCIATED WITH THE INTERFACE OF TWO LIQUIDS | $1,451 | $1,103 | Not Implemented |
LS2201 # 08 Y:2022 | 08 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $15,305 | $31,464 | Implemented |
LS2201 # 09 Y:2022 | 09 | 2022 | OPTIMIZE PLANT POWER FACTOR | $464 | $3,415 | Not Implemented |
LS2201 # 10 Y:2022 | 10 | 2022 | USE SOLAR HEAT TO MAKE ELECTRICTY | $41,481 | $646,020 | Not Implemented |
MZ0320 # 01 Y:2021 | 01 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $10,092 | $12,000 | Not Implemented |
MZ0320 # 02 Y:2021 | 02 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,821 | $240 | Implemented |
MZ0320 # 03 Y:2021 | 03 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,470 | $9,762 | Not Implemented |
MZ0320 # 04 Y:2021 | 04 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,708 | $15,605 | Implemented |
MZ0320 # 05 Y:2021 | 05 | 2021 | INSULATE BARE EQUIPMENT | $375 | $389 | Not Implemented |
MZ0320 # 06 Y:2021 | 06 | 2021 | SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING | $298 | $1,226 | Not Implemented |
MZ0320 # 07 Y:2021 | 07 | 2021 | INSTALL OCCUPANCY SENSORS | $279 | $360 | Implemented |
MZ0316 # 01 Y:2021 | 01 | 2021 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,730 | $7,800 | Implemented |
MZ0316 # 02 Y:2021 | 02 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,326 | $480 | Implemented |
MZ0316 # 03 Y:2021 | 03 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $398 | $80 | Implemented |
MZ0316 # 04 Y:2021 | 04 | 2021 | USE RADIANT HEATER FOR SPOT HEATING | $24,773 | $86,550 | Not Implemented |
MZ0316 # 05 Y:2021 | 05 | 2021 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $12,219 | $40,130 | Not Implemented |
MZ0316 # 06 Y:2021 | 06 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,527 | $1,395 | Not Implemented |
MZ0316 # 07 Y:2021 | 07 | 2021 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $2,786 | $11,055 | Implemented |
MZ0316 # 08 Y:2021 | 08 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,866 | $3,614 | Implemented |
MZ0316 # 09 Y:2021 | 09 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $9,528 | $625 | Not Implemented |
MZ0316 # 10 Y:2021 | 10 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,220 | $3,485 | Implemented |
SD0616 # 01 Y:2021 | 01 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,932 | $1,479 | Implemented |