Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,176
matching recommendationsNAICS | 3323 | Architectural and Structural Metals Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0052 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $168 | $97 | Not Implemented |
UA0052 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,369 | $640 | Not Implemented |
UA0052 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,183 | $1,500 | Implemented |
UA0052 # 06 Y:2010 | 06 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $2,198 | $5,028 | Not Implemented |
UA0052 # 07 Y:2010 | 07 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $3,116 | $850 | Not Implemented |
UA0052 # 08 Y:2010 | 08 | 2010 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $11,400 | $10,000 | Not Implemented |
DL0050 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,623 | $100 | Not Implemented |
DL0050 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,070 | $300 | Implemented |
DL0050 # 03 Y:2010 | 03 | 2010 | INSTALL SET-BACK TIMERS | $1,236 | $300 | Not Implemented |
DL0050 # 04 Y:2010 | 04 | 2010 | COVER OPEN TANKS | $263 | $275 | Not Implemented |
DL0050 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,850 | $34,600 | Implemented |
NC0404 # 01 Y:2010 | 01 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $4,526 | $6,090 | Implemented |
NC0404 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $420 | $200 | Implemented |
NC0404 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $435 | $1,890 | Implemented |
NC0404 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,935 | $40 | Not Implemented |
BD0371 # 01 Y:2010 | 01 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $18,738 | $7,700 | Not Implemented |
BD0371 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,099 | $59,000 | Implemented |
BD0371 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,855 | $4,900 | Implemented |
BD0371 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,181 | $10 | Implemented |
BD0371 # 05 Y:2010 | 05 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,027 | $10,100 | Not Implemented |
BD0371 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,199 | $8,511 | Implemented |
BD0371 # 07 Y:2010 | 07 | 2010 | USE SYNTHETIC LUBRICANT | $1,752 | $900 | Not Implemented |
BD0371 # 08 Y:2010 | 08 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $826 | $1,200 | Not Implemented |
BD0371 # 09 Y:2010 | 09 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $383 | $300 | n/a |
UD0815 # 01 Y:2010 | 01 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,258 | $0 | Implemented |