Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
437
matching recommendationsNAICS | 33231 | Plate Work and Fabricated Structural Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0034 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,489 | $55,984 | Implemented |
DL0034 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,600 | $4,000 | Implemented |
DL0034 # 06 Y:2009 | 06 | 2009 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,735 | $18,313 | Implemented |
DL0034 # 07 Y:2009 | 07 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $700 | $0 | Implemented |
DL0034 # 08 Y:2009 | 08 | 2009 | ADD AREA LIGHTING SWITCHES | $313 | $197 | Implemented |
AM0548 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $100,400 | $59,650 | Implemented |
AM0548 # 03 Y:2008 | 03 | 2008 | INSTALL SKYLIGHTS | $8,620 | $17,170 | Implemented |
AM0548 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,000 | $350 | Implemented |
AM0548 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,000 | $0 | Implemented |
AM0548 # 07 Y:2008 | 07 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $620 | $0 | Implemented |
AM0548 # 08 Y:2008 | 08 | 2008 | USE SYNTHETIC LUBRICANT | $365 | $0 | Implemented |
AM0548 # 09 Y:2008 | 09 | 2008 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $265 | $0 | Implemented |
OK0761 # 01 Y:2008 | 01 | 2008 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,213 | $0 | Implemented |
OK0761 # 02 Y:2008 | 02 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,263 | $4,638 | Implemented |
OK0761 # 03 Y:2008 | 03 | 2008 | INSTALL OCCUPANCY SENSORS | $525 | $2,871 | Implemented |
OK0761 # 04 Y:2008 | 04 | 2008 | INSTALL SET-BACK TIMERS | $3,105 | $1,908 | Implemented |
OK0761 # 05 Y:2008 | 05 | 2008 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $5,200 | $0 | Implemented |
MS0316 # 02 Y:2007 | 02 | 2007 | COMBINE UTILITY METERS | $15,244 | $0 | Implemented |
MS0316 # 03 Y:2007 | 03 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,294 | $247 | Implemented |
MS0316 # 04 Y:2007 | 04 | 2007 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $1,523 | $1,575 | Implemented |
TA0125 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,191 | $155 | Implemented |
TA0125 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $894 | $0 | Implemented |
TA0125 # 03 Y:2006 | 03 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $268,990 | $0 | Implemented |
TA0125 # 04 Y:2006 | 04 | 2006 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $421 | $0 | Implemented |
SU0243 # 01 Y:2006 | 01 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $18,077 | $0 | Implemented |