Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,123
matching recommendationsNAICS | 33232 | Ornamental and Architectural Metal Products Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0216 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $416 | $981 | Implemented |
SU0216 # 07 Y:2005 | 07 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,140 | $3,550 | Not Implemented |
SU0216 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,013 | $17,360 | Implemented |
SU0216 # 09 Y:2005 | 09 | 2005 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $389 | $1,520 | Not Implemented |
AS0404 # 01 Y:2005 | 01 | 2005 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $60,950 | $0 | Not Implemented |
AS0404 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,578 | $45,427 | Not Implemented |
AS0404 # 03 Y:2005 | 03 | 2005 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,521 | $11,360 | Not Implemented |
AS0404 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,338 | $3,000 | Not Implemented |
AS0404 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,106 | $50 | Not Implemented |
AS0404 # 06 Y:2005 | 06 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $197 | $97 | Not Implemented |
UF0363 # 01 Y:2005 | 01 | 2005 | INSTALL SKYLIGHTS | $13,867 | $51,456 | Not Implemented |
UF0363 # 02 Y:2005 | 02 | 2005 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $12,819 | $20,000 | Not Implemented |
UF0363 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,583 | $934 | Implemented |
UF0363 # 04 Y:2005 | 04 | 2005 | USE PHOTOCELL CONTROLS | $6,875 | $2,070 | Implemented |
UF0363 # 05 Y:2005 | 05 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,898 | $0 | Implemented |
UF0363 # 06 Y:2005 | 06 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $3,044 | $6,525 | Implemented |
UF0363 # 07 Y:2005 | 07 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,902 | $5,156 | Implemented |
UF0363 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $1,382 | $1,026 | Implemented |
UF0363 # 09 Y:2005 | 09 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $630 | $1,935 | Implemented |
UF0363 # 10 Y:2005 | 10 | 2005 | INSTALL BACK-UP EQUIPMENT | $903,847 | $67,712 | Implemented |
MI0108 # 01 Y:2005 | 01 | 2005 | REDUCE OR ELIMINATE WASTE | $89,286 | $5,260 | Not Implemented |
MI0108 # 02 Y:2005 | 02 | 2005 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $24,230 | $5,100 | Not Implemented |
MI0108 # 03 Y:2005 | 03 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,363 | $120 | Not Implemented |
MI0108 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,902 | $50 | Not Implemented |
MI0108 # 05 Y:2005 | 05 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $320 | $320 | Not Implemented |