Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

55

matching recommendations
Reset
NAICS 3324 Boiler, Tank, and Shipping Container Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0061 # 04 Y:2015 04 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,688 $5,526 Implemented
WM0061 # 05 Y:2015 05 2015 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,426 $1,849 Implemented
WM0061 # 06 Y:2015 06 2015 USE SYNTHETIC LUBRICANT $2,017 $1,155 Implemented
WM0061 # 07 Y:2015 07 2015 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $721 $2,000 Not Implemented
WM0061 # 08 Y:2015 08 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,308 $23,529 Not Implemented
WM0061 # 09 Y:2015 09 2015 USE MAGNETIC TECHNOLOGY TO TREAT WATER $1,996 $4,600 Not Implemented
WM0061 # 10 Y:2015 10 2015 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $658 $750 Not Implemented
WI0473 # 05 Y:2004 05 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $619 $640 Implemented
WI0473 # 04 Y:2004 04 2004 INSTALL TIMERS AND/OR THERMOSTATS $1,028 $100 Implemented
WI0473 # 03 Y:2004 03 2004 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $12,156 $11,000 Not Implemented
WI0473 # 02 Y:2004 02 2004 REDUCE VENTILATION AIR $16,661 $32,000 Not Implemented
WI0473 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,462 $53,600 Implemented
WI0466 # 02 Y:2004 02 2004 INSTALL TIMERS AND/OR THERMOSTATS $7,059 $1,200 Not Implemented
WI0466 # 07 Y:2004 07 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,231 $740 Not Implemented
WI0466 # 06 Y:2004 06 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,755 $1,000 Not Implemented
WI0466 # 05 Y:2004 05 2004 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $3,550 $0 Not Implemented
WI0466 # 04 Y:2004 04 2004 USE EVAPORATION TO CONCENTRATE MATERIAL $4,435 $10,000 Not Implemented
WI0466 # 03 Y:2004 03 2004 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $4,749 $9,500 Not Implemented
WI0466 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,842 $30,850 Implemented
WI0453 # 06 Y:2003 06 2003 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $4,657 $20,000 Not Implemented
WI0453 # 05 Y:2003 05 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,121 $1,280 Implemented
WI0453 # 04 Y:2003 04 2003 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $3,824 $8,700 Not Implemented
WI0453 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,041 $18,315 Implemented
WI0453 # 02 Y:2003 02 2003 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $22,445 $40,000 Not Implemented
WI0453 # 01 Y:2003 01 2003 RECOVER WASTE HEAT FROM EQUIPMENT $47,771 $18,500 Not Implemented