Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
48
matching recommendationsNAICS | 33261 | Spring and Wire Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0346 # 05 Y:2023 | 05 | 2023 | INSTALL OCCUPANCY SENSORS | $146 | $200 | Implemented |
MZ0346 # 02 Y:2023 | 02 | 2023 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $967 | $320 | Not Implemented |
MZ0346 # 04 Y:2023 | 04 | 2023 | TURN OFF EQUIPMENT WHEN NOT IN USE | $425 | $485 | Not Implemented |
MZ0346 # 03 Y:2023 | 03 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,048 | $6,536 | Not Implemented |
MZ0346 # 01 Y:2023 | 01 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $825 | $2,925 | Implemented |
WM0060 # 01 Y:2015 | 01 | 2015 | REPLACE BOILER | $24,302 | $20,000 | Not Implemented |
WM0060 # 06 Y:2015 | 06 | 2015 | INSTALL OCCUPANCY SENSORS | $786 | $3,000 | Implemented |
WM0060 # 04 Y:2015 | 04 | 2015 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $3,701 | $1,218 | Implemented |
WM0060 # 02 Y:2015 | 02 | 2015 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,761 | $2,291 | Implemented |
WM0060 # 07 Y:2015 | 07 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $680 | $255 | Implemented |
WM0060 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,355 | $0 | Implemented |
WM0060 # 05 Y:2015 | 05 | 2015 | REPAIR AND ELIMINATE STEAM LEAKS | $1,080 | $110 | Implemented |
BD0395 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $1,621 | $825 | Implemented |
BD0395 # 04 Y:2011 | 04 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $1,380 | $1,500 | Not Implemented |
BD0395 # 02 Y:2011 | 02 | 2011 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,656 | $2,150 | Not Implemented |
BD0395 # 06 Y:2011 | 06 | 2011 | USE PHOTOCELL CONTROLS | $615 | $375 | Implemented |
BD0395 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,465 | $34,827 | Implemented |
BD0395 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $888 | $1,000 | Not Implemented |
IC0178 # 03 Y:2010 | 03 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,171 | $709 | Not Implemented |
IC0178 # 04 Y:2010 | 04 | 2010 | INSTALL OCCUPANCY SENSORS | $1,180 | $3,286 | Implemented |
IC0178 # 05 Y:2010 | 05 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $754 | $4,000 | Implemented |
IC0178 # 06 Y:2010 | 06 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,949 | $6,377 | Not Implemented |
IC0178 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,701 | $2,530 | Not Implemented |
IC0178 # 08 Y:2010 | 08 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $843 | $0 | Not Implemented |