Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

26

matching recommendations
Reset
NAICS 33261 Spring and Wire Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0173 # 07 Y:2003 07 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $1,069 $0 Not Implemented
LE0173 # 06 Y:2003 06 2003 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,247 $750 Not Implemented
LE0173 # 05 Y:2003 05 2003 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $6,047 $10,000 Not Implemented
LE0173 # 04 Y:2003 04 2003 PAY UTILITY BILLS ON TIME $10,900 $0 Not Implemented
LE0173 # 03 Y:2003 03 2003 PAY UTILITY BILLS ON TIME $14,409 $0 Not Implemented
LE0173 # 02 Y:2003 02 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $32,033 $0 Not Implemented
LE0173 # 01 Y:2003 01 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $37,011 $0 Not Implemented
AM0443 # 08 Y:2003 08 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $110 $115 n/a
AM0443 # 07 Y:2003 07 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $200 $50 n/a
AM0443 # 06 Y:2003 06 2003 REUSE RAGS UNTIL COMPLETELY SOILED $970 $0 n/a
AM0443 # 05 Y:2003 05 2003 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,590 $250 n/a
AM0443 # 04 Y:2003 04 2003 USE SYNTHETIC LUBRICANT $2,660 $0 n/a
AM0443 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,700 $700 n/a
AM0443 # 02 Y:2003 02 2003 INSULATE BARE EQUIPMENT $19,270 $2,100 n/a
AM0443 # 01 Y:2003 01 2003 INSTALL EQUIPMENT TO MOVE PRODUCT $51,825 $25,200 n/a
AM0435 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $20,300 $500 Implemented
AM0435 # 06 Y:2003 06 2003 USE PHOTOCELL CONTROLS $775 $75 Implemented
AM0435 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $950 $235 Not Implemented
AM0435 # 04 Y:2003 04 2003 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,100 $0 Implemented
AM0435 # 03 Y:2003 03 2003 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE $4,670 $0 Not Implemented
AM0435 # 02 Y:2003 02 2003 USE SYNTHETIC LUBRICANT $12,740 $0 Not Implemented
IC0051 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,535 $6,726 Not Implemented
IC0051 # 02 Y:2003 02 2003 INSTALL OCCUPANCY SENSORS $136 $141 Not Implemented
IC0051 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,877 $2,600 Implemented
IC0051 # 04 Y:2003 04 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $185 $150 Not Implemented