Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,135
matching recommendationsNAICS | 3327 | Machine Shops; Turned Product; and Screw, Nut, and Bolt Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0174 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $1,133 | $2,415 | Not Implemented |
IC0174 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $287 | $678 | Not Implemented |
IC0174 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,326 | $4,485 | Implemented |
IC0174 # 06 Y:2010 | 06 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,206 | $0 | Not Implemented |
IC0174 # 07 Y:2010 | 07 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,895 | $2,611 | Not Implemented |
IC0174 # 08 Y:2010 | 08 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,429 | $6,584 | Not Implemented |
IC0174 # 09 Y:2010 | 09 | 2010 | AVOID EMERGENCY REWIND OF MOTORS | $1,054 | $5,472 | Not Implemented |
IC0174 # 10 Y:2010 | 10 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,996 | $934 | Not Implemented |
IC0174 # 11 Y:2010 | 11 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,966 | $7,927 | Not Implemented |
IC0174 # 12 Y:2010 | 12 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $257 | $0 | Not Implemented |
LE0304 # 01 Y:2010 | 01 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $300,000 | $40,932 | Not Implemented |
LE0304 # 02 Y:2010 | 02 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $55,099 | $39,415 | Not Implemented |
LE0304 # 03 Y:2010 | 03 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $16,822 | $18,000 | Not Implemented |
LE0304 # 04 Y:2010 | 04 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $15,355 | $100,000 | Not Implemented |
LE0304 # 05 Y:2010 | 05 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $12,804 | $30 | Implemented |
LE0304 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,592 | $15,000 | Not Implemented |
LE0304 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,396 | $273 | Implemented |
LE0304 # 08 Y:2010 | 08 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,370 | $0 | Not Implemented |
LE0304 # 09 Y:2010 | 09 | 2010 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,073 | $5,740 | Not Implemented |
LE0304 # 10 Y:2010 | 10 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $803 | $2,400 | Not Implemented |
LE0304 # 11 Y:2010 | 11 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,692 | $14,758 | Implemented |
LE0304 # 12 Y:2010 | 12 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,240 | $11,654 | Implemented |
OK0779 # 01 Y:2009 | 01 | 2009 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $36,513 | $900,000 | Not Implemented |
OK0779 # 02 Y:2009 | 02 | 2009 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $122,608 | $160,000 | Not Implemented |
OK0779 # 03 Y:2009 | 03 | 2009 | USE POWER DURING OFF-PEAK PERIODS | $30,940 | $0 | Not Implemented |