Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,135
matching recommendationsNAICS | 3327 | Machine Shops; Turned Product; and Screw, Nut, and Bolt Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0264 # 03 Y:2008 | 03 | 2008 | USE SYNTHETIC LUBRICANT | $4,440 | $0 | Not Implemented |
SU0264 # 04 Y:2008 | 04 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,015 | $200 | Implemented |
SU0264 # 05 Y:2008 | 05 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $308 | $444 | Not Implemented |
SU0264 # 06 Y:2008 | 06 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,415 | $24,120 | Implemented |
WV0364 # 01 Y:2007 | 01 | 2007 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $37,506 | $7,700 | Not Implemented |
WV0364 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $29,507 | $12,903 | Implemented |
WV0364 # 03 Y:2007 | 03 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $28,283 | $0 | Implemented |
WV0364 # 04 Y:2007 | 04 | 2007 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $25,424 | $32,700 | Implemented |
WV0364 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,229 | $40,317 | Implemented |
WV0364 # 06 Y:2007 | 06 | 2007 | DEVELOP A REPAIR/REPLACE POLICY | $12,941 | $840 | Implemented |
WV0364 # 07 Y:2007 | 07 | 2007 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $7,757 | $10,000 | Not Implemented |
WV0364 # 08 Y:2007 | 08 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,774 | $640 | Not Implemented |
WV0364 # 09 Y:2007 | 09 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $3,398 | $1,070 | Not Implemented |
WV0364 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,627 | $5,578 | Implemented |
WV0364 # 11 Y:2007 | 11 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,393 | $375 | Implemented |
WV0364 # 12 Y:2007 | 12 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,696 | $140 | Implemented |
WV0364 # 13 Y:2007 | 13 | 2007 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,174 | $2,445 | Not Implemented |
UM0323 # 01 Y:2007 | 01 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,469 | $3,500 | Implemented |
UM0323 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $7,978 | $1,000 | Implemented |
UM0323 # 03 Y:2007 | 03 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $15,247 | $2,653 | Implemented |
UM0323 # 04 Y:2007 | 04 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,815 | $500 | Implemented |
UM0323 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,347 | $8,175 | Implemented |
UM0323 # 06 Y:2007 | 06 | 2007 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $6,157 | $1,836 | Implemented |
UM0323 # 07 Y:2007 | 07 | 2007 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,934 | $6,822 | Not Implemented |
UM0323 # 08 Y:2007 | 08 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,360 | $100 | Not Implemented |