Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,135
matching recommendationsNAICS | 3327 | Machine Shops; Turned Product; and Screw, Nut, and Bolt Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0323 # 09 Y:2007 | 09 | 2007 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $2,628 | $4,248 | Implemented |
UM0323 # 10 Y:2007 | 10 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,122 | $1,000 | Implemented |
UM0323 # 11 Y:2007 | 11 | 2007 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $946 | $1,000 | Implemented |
UM0323 # 12 Y:2007 | 12 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $615 | $75 | Implemented |
UM0323 # 13 Y:2007 | 13 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $513 | $206 | Implemented |
UM0313 # 01 Y:2006 | 01 | 2006 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,823 | $0 | Implemented |
UM0313 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,498 | $9,857 | Not Implemented |
UM0313 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,655 | $225 | Implemented |
UM0313 # 04 Y:2006 | 04 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,007 | $1,100 | Not Implemented |
UM0313 # 05 Y:2006 | 05 | 2006 | INSULATE BARE EQUIPMENT | $431 | $323 | Not Implemented |
UM0313 # 06 Y:2006 | 06 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $56 | $0 | Not Implemented |
UM0304 # 01 Y:2006 | 01 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,618 | $2,500 | Implemented |
UM0304 # 02 Y:2006 | 02 | 2006 | OPTIMIZE PLANT POWER FACTOR | $9,510 | $40,185 | Not Implemented |
UM0304 # 03 Y:2006 | 03 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,445 | $875 | Implemented |
UM0304 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,663 | $11,910 | Not Implemented |
UM0304 # 05 Y:2006 | 05 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,372 | $1,750 | Implemented |
UM0304 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,496 | $1,000 | Implemented |
UM0304 # 07 Y:2006 | 07 | 2006 | COVER OPEN TANKS | $810 | $384 | Implemented |
UM0304 # 08 Y:2006 | 08 | 2006 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $796 | $325 | Implemented |
UM0304 # 09 Y:2006 | 09 | 2006 | INSTALL OCCUPANCY SENSORS | $594 | $594 | Implemented |
UM0304 # 10 Y:2006 | 10 | 2006 | COVER OPEN TANKS | $327 | $475 | Implemented |
WI0516 # 01 Y:2006 | 01 | 2006 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $987,800 | $0 | Not Implemented |
WI0516 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,265 | $33,480 | Implemented |
WI0516 # 03 Y:2006 | 03 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,330 | $1,600 | Not Implemented |
WI0516 # 04 Y:2006 | 04 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,311 | $1,000 | Implemented |