Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsNAICS | 33271 | Machine Shops |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0436 # 09 Y:2017 | 09 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,214 | $3,195 | Implemented |
SU0436 # 05 Y:2017 | 05 | 2017 | ELIMINATE/REDUCE AN OPERATION | $4,066 | $4,830 | Implemented |
SU0436 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $800 | $741 | Implemented |
SU0436 # 03 Y:2017 | 03 | 2017 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $3,447 | $2,277 | Implemented |
SU0436 # 01 Y:2017 | 01 | 2017 | DISCONNECT BALLASTS | $95 | $0 | Implemented |
SU0422 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,567 | $25,530 | Implemented |
SU0422 # 07 Y:2016 | 07 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $189 | $332 | Implemented |
SU0422 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $153 | $150 | Implemented |
SU0422 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $484 | $164 | Implemented |
SU0422 # 01 Y:2016 | 01 | 2016 | ELIMINATE/REDUCE AN OPERATION | $1,752 | $0 | Implemented |
SU0369 # 03 Y:2014 | 03 | 2014 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $463 | $0 | Implemented |
SU0369 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,078 | $20,000 | Implemented |
SU0331 # 05 Y:2013 | 05 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $142 | $299 | Implemented |
SU0331 # 04 Y:2013 | 04 | 2013 | INSTALL SET-BACK TIMERS | $299 | $228 | Implemented |
SU0331 # 03 Y:2013 | 03 | 2013 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $19 | $0 | Implemented |
SU0331 # 02 Y:2013 | 02 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $211 | $0 | Implemented |
SU0331 # 01 Y:2013 | 01 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $808 | $0 | Implemented |
SU0309 # 01 Y:2011 | 01 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $201 | $0 | Implemented |
SU0309 # 08 Y:2011 | 08 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $1,442 | $16,500 | Implemented |
SU0309 # 07 Y:2011 | 07 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $116 | $1,258 | Implemented |
SU0309 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $68 | $228 | Implemented |
SU0309 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $255 | $147 | Implemented |