Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
38
matching recommendationsNAICS | 33271 | Machine Shops |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0270 # 07 Y:2003 | 07 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,894 | $500 | Not Implemented |
WV0270 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,616 | $0 | Implemented |
WV0270 # 13 Y:2003 | 13 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,088 | $2,000 | Not Implemented |
WV0270 # 12 Y:2003 | 12 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,750 | $4,590 | Implemented |
WV0270 # 11 Y:2003 | 11 | 2003 | INSTALL OCCUPANCY SENSORS | $2,244 | $1,450 | Implemented |
WV0270 # 10 Y:2003 | 10 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,296 | $735 | Not Implemented |
WV0270 # 09 Y:2003 | 09 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,937 | $250 | Implemented |
WV0270 # 06 Y:2003 | 06 | 2003 | INSULATE BARE EQUIPMENT | $7,108 | $1,418 | Implemented |
WV0270 # 04 Y:2003 | 04 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,034 | $250 | Not Implemented |
WV0270 # 05 Y:2003 | 05 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,121 | $150 | Implemented |
WV0270 # 03 Y:2003 | 03 | 2003 | DEVELOP A REPAIR/REPLACE POLICY | $6,214 | $625 | Implemented |
WV0270 # 08 Y:2003 | 08 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,379 | $810 | Not Implemented |
WV0270 # 02 Y:2003 | 02 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,533 | $0 | Implemented |
WI0445 # 01 Y:2003 | 01 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $4,725 | $0 | Implemented |
WI0445 # 02 Y:2003 | 02 | 2003 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $3,022 | $10,000 | n/a |
WI0445 # 03 Y:2003 | 03 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,188 | $4,400 | Not Implemented |
WI0445 # 04 Y:2003 | 04 | 2003 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $1,188 | $1,000 | Not Implemented |
WI0445 # 05 Y:2003 | 05 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $1,111 | $2,500 | Not Implemented |
WI0445 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $422 | $640 | Implemented |
WI0444 # 01 Y:2003 | 01 | 2003 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $6,597 | $9,000 | Implemented |
WI0444 # 02 Y:2003 | 02 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $4,807 | $7,500 | Not Implemented |
WI0444 # 03 Y:2003 | 03 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,189 | $8,655 | Implemented |
WI0444 # 04 Y:2003 | 04 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,383 | $2,000 | Not Implemented |
WI0444 # 05 Y:2003 | 05 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,301 | $1,424 | Not Implemented |
WI0444 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $983 | $740 | Implemented |