Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
57
matching recommendationsNAICS | 332710 | Machine Shops |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0516 # 01 Y:2006 | 01 | 2006 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $987,800 | $0 | Not Implemented |
WI0502 # 08 Y:2005 | 08 | 2005 | IMPROVE LUBRICATION PRACTICES | $1,579 | $1,238 | Not Implemented |
WI0502 # 10 Y:2005 | 10 | 2005 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $1,374 | $1,500 | Not Implemented |
WI0502 # 09 Y:2005 | 09 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,524 | $1,280 | Not Implemented |
WI0502 # 07 Y:2005 | 07 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,670 | $520 | Not Implemented |
WI0502 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,919 | $0 | Not Implemented |
WI0502 # 05 Y:2005 | 05 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $2,699 | $0 | Not Implemented |
WI0502 # 04 Y:2005 | 04 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,880 | $0 | Not Implemented |
WI0502 # 03 Y:2005 | 03 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,880 | $0 | Not Implemented |
WI0502 # 02 Y:2005 | 02 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $4,177 | $9,500 | Not Implemented |
WI0502 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,862 | $27,000 | Not Implemented |
WI0465 # 02 Y:2004 | 02 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,432 | $11,183 | Implemented |
WI0465 # 01 Y:2004 | 01 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,760 | $16,000 | Implemented |
WI0465 # 03 Y:2004 | 03 | 2004 | INSTALL OCCUPANCY SENSORS | $3,044 | $1,680 | Not Implemented |
WI0465 # 04 Y:2004 | 04 | 2004 | USE EVAPORATION TO CONCENTRATE MATERIAL | $5,458 | $18,000 | Not Implemented |
WI0465 # 06 Y:2004 | 06 | 2004 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $1,882 | $2,500 | Not Implemented |
WI0465 # 07 Y:2004 | 07 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,126 | $700 | Implemented |
WI0465 # 08 Y:2004 | 08 | 2004 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $727 | $0 | Not Implemented |
WI0465 # 05 Y:2004 | 05 | 2004 | INSTALL AUTOMATIC STACK DAMPER | $2,736 | $1,900 | Not Implemented |
WI0445 # 03 Y:2003 | 03 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,188 | $4,400 | Not Implemented |
WI0445 # 01 Y:2003 | 01 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $4,725 | $0 | Implemented |
WI0445 # 02 Y:2003 | 02 | 2003 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $3,022 | $10,000 | n/a |
WI0445 # 04 Y:2003 | 04 | 2003 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $1,188 | $1,000 | Not Implemented |
WI0445 # 05 Y:2003 | 05 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $1,111 | $2,500 | Not Implemented |
WI0445 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $422 | $640 | Implemented |