Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,834
matching recommendationsNAICS | 3328 | Coating, Engraving, Heat Treating, and Allied Activities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0646 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $23,468 | $24,468 | Implemented |
OR0646 # 05 Y:2015 | 05 | 2015 | ISOLATE HOT OR COLD EQUIPMENT | $44,385 | $3,000 | Implemented |
TT0151 # 01 Y:2015 | 01 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,852 | $30,000 | Not Implemented |
TT0151 # 02 Y:2015 | 02 | 2015 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $13,548 | $21,700 | Not Implemented |
TT0151 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $11,094 | $20,000 | Not Implemented |
TT0151 # 04 Y:2015 | 04 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,096 | $600 | Not Implemented |
TT0151 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $1,197 | $600 | Not Implemented |
TT0151 # 06 Y:2015 | 06 | 2015 | DISCONNECT BALLASTS | $112 | $10 | Not Implemented |
LE0389 # 01 Y:2015 | 01 | 2015 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,935 | $450 | Implemented |
LE0389 # 02 Y:2015 | 02 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,547 | $4,500 | Implemented |
LE0389 # 03 Y:2015 | 03 | 2015 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $21,418 | $21,650 | Implemented |
LE0389 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $642 | $1,000 | Implemented |
LE0389 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,458 | $81,373 | Implemented |
LE0389 # 06 Y:2015 | 06 | 2015 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,484 | $20,000 | Not Implemented |
UA0130 # 01 Y:2014 | 01 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $15,715 | $35,154 | Not Implemented |
UA0130 # 02 Y:2014 | 02 | 2014 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,506 | $6,410 | Not Implemented |
UA0130 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $2,774 | $200 | Implemented |
UA0130 # 04 Y:2014 | 04 | 2014 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,266 | $0 | Implemented |
UA0130 # 05 Y:2014 | 05 | 2014 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $6,867 | $4,120 | Not Implemented |
UA0130 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,986 | $2,522 | Not Implemented |
UA0130 # 07 Y:2014 | 07 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,890 | $100 | Implemented |
UD0913 # 01 Y:2014 | 01 | 2014 | UPGRADE CONVEYORS | $528 | $255 | Not Implemented |
UD0913 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $615 | $570 | Implemented |
UD0913 # 03 Y:2014 | 03 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $511 | $1,275 | Implemented |
UD0913 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,643 | $8,500 | Not Implemented |