Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,834
matching recommendationsNAICS | 33281 | Coating, Engraving, Heat Treating, and Allied Activities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0445 # 04 Y:2017 | 04 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $525 | $750 | Implemented |
LE0445 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,741 | $6,692 | Implemented |
SU0450 # 01 Y:2017 | 01 | 2017 | ELIMINATE/REDUCE AN OPERATION | $7,150 | $4,350 | Not Implemented |
SU0450 # 02 Y:2017 | 02 | 2017 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $2,004 | $1,340 | Implemented |
SU0450 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,719 | $4,657 | Implemented |
SU0450 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $402 | $508 | Not Implemented |
SU0450 # 05 Y:2017 | 05 | 2017 | REDUCE VENTILATION AIR | $340 | $512 | Implemented |
SU0450 # 06 Y:2017 | 06 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,933 | $22,600 | Not Implemented |
SU0450 # 07 Y:2017 | 07 | 2017 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $158 | $374 | Not Implemented |
GT0901 # 01 Y:2017 | 01 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $89,452 | $5,000 | Implemented |
GT0901 # 02 Y:2017 | 02 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,992 | $10,805 | Implemented |
GT0901 # 03 Y:2017 | 03 | 2017 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,259 | $2,654 | Not Implemented |
GT0901 # 04 Y:2017 | 04 | 2017 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $8,249 | $18,040 | Not Implemented |
GT0901 # 05 Y:2017 | 05 | 2017 | USE SOLAR HEAT FOR HEAT | $52,084 | $187,502 | Not Implemented |
MI0313 # 01 Y:2017 | 01 | 2017 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,711 | $620 | Not Implemented |
MI0313 # 02 Y:2017 | 02 | 2017 | USE PHOTOCELL CONTROLS | $6,519 | $720 | Implemented |
MI0313 # 03 Y:2017 | 03 | 2017 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,171 | $1,160 | Implemented |
MI0313 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,626 | $4,300 | Not Implemented |
MI0313 # 05 Y:2017 | 05 | 2017 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $2,803 | $1,580 | Not Implemented |
MI0313 # 06 Y:2017 | 06 | 2017 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $1,082 | $249 | Implemented |
MI0313 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $992 | $3,884 | Not Implemented |
MI0313 # 08 Y:2017 | 08 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $992 | $1,660 | Implemented |
MI0313 # 09 Y:2017 | 09 | 2017 | INSTALL OCCUPANCY SENSORS | $164 | $574 | Implemented |
MA0772 # 01 Y:2017 | 01 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,553 | $10,235 | Not Implemented |