Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
261
matching recommendationsNAICS | 33281 | Coating, Engraving, Heat Treating, and Allied Activities |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0515 # 08 Y:2015 | 08 | 2015 | INSTALL OCCUPANCY SENSORS | $975 | $3,180 | Implemented |
WV0515 # 07 Y:2015 | 07 | 2015 | INSTALL SET-BACK TIMERS | $1,310 | $1,175 | Implemented |
WV0515 # 06 Y:2015 | 06 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,694 | $6,400 | Not Implemented |
WV0515 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $1,835 | $920 | Implemented |
WV0515 # 04 Y:2015 | 04 | 2015 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $4,181 | $11,220 | Not Implemented |
WV0515 # 03 Y:2015 | 03 | 2015 | INSTALL OCCUPANCY SENSORS | $4,682 | $1,278 | Implemented |
WV0515 # 02 Y:2015 | 02 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,569 | $1,700 | Implemented |
WV0515 # 01 Y:2015 | 01 | 2015 | INSULATE FEEDWATER TANK | $13,405 | $6,253 | Not Implemented |
UD0913 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $615 | $570 | Implemented |
UD0913 # 01 Y:2014 | 01 | 2014 | UPGRADE CONVEYORS | $528 | $255 | Not Implemented |
UD0913 # 03 Y:2014 | 03 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $511 | $1,275 | Implemented |
UD0913 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,643 | $8,500 | Not Implemented |
UD0913 # 06 Y:2014 | 06 | 2014 | REPLACE BOILER | $19,697 | $163,500 | Not Implemented |
UD0913 # 05 Y:2014 | 05 | 2014 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $1,623 | $7,000 | Not Implemented |
UD0913 # 12 Y:2014 | 12 | 2014 | TREAT AND REUSE RINSE WATERS | $15,837 | $10,000 | Not Implemented |
UD0913 # 11 Y:2014 | 11 | 2014 | USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS | $27,921 | $55,000 | Not Implemented |
UD0913 # 10 Y:2014 | 10 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $414,555 | $27,000 | Not Implemented |
UD0913 # 08 Y:2014 | 08 | 2014 | COVER OPEN TANKS | $3,270 | $6,780 | Implemented |
UD0913 # 07 Y:2014 | 07 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,485 | $5,000 | Not Implemented |
UD0913 # 09 Y:2014 | 09 | 2014 | INSTALL AUTOMATIC STACK DAMPER | $2,665 | $0 | Implemented |
UD0876 # 04 Y:2013 | 04 | 2013 | BASE UTILITY CHARGES ON USAGE RATHER THAN AREA OCCUPIED | $1,416 | $1,400 | Implemented |
UD0876 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,184 | $0 | Implemented |
UD0876 # 02 Y:2013 | 02 | 2013 | OPTIMIZE PLANT POWER FACTOR | $3,308 | $12,000 | Not Implemented |
UD0876 # 11 Y:2013 | 11 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $489 | $50 | Not Implemented |
UD0876 # 13 Y:2013 | 13 | 2013 | AIR CONDITION ONLY SPACE NECESSARY | $1,344 | $0 | Implemented |