Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
69
matching recommendationsNAICS | 332811 | Metal Heat Treating |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0531 # 07 Y:2016 | 07 | 2016 | USE SAND FOR OTHER PURPOSES (EG CONSTRUCTION FILL, COVER FOR MUNICIPAL LANDFILLS) | $2,730 | $2,795 | Not Implemented |
WV0531 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,225 | $4,010 | Implemented |
WV0531 # 09 Y:2016 | 09 | 2016 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $956 | $1,000 | Implemented |
UD0856 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,482 | $8,415 | Not Implemented |
UD0856 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $720 | $300 | Not Implemented |
UD0856 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $441 | $2,025 | Not Implemented |
UD0856 # 04 Y:2012 | 04 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,690 | $5,370 | Not Implemented |
UD0856 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,442 | $2,160 | Not Implemented |
UD0856 # 06 Y:2012 | 06 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,802 | $700 | Not Implemented |
UD0856 # 07 Y:2012 | 07 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,339 | $1,500 | Not Implemented |
UD0856 # 08 Y:2012 | 08 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $782 | $50 | Not Implemented |
UD0856 # 09 Y:2012 | 09 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $240 | $1,000 | Not Implemented |
UD0856 # 10 Y:2012 | 10 | 2012 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $11,452 | $30,000 | Not Implemented |
UD0856 # 11 Y:2012 | 11 | 2012 | REDUCE VENTILATION AIR | $4,756 | $8,600 | Not Implemented |
UD0856 # 12 Y:2012 | 12 | 2012 | USE SOLAR HEAT TO MAKE ELECTRICTY | $27,298 | $181,738 | Not Implemented |
UM0372 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $88 | $1,000 | Implemented |
UM0372 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $2,083 | $2,500 | Implemented |
UM0372 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $645 | $200 | Implemented |
UM0372 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $265 | $2,000 | Implemented |
UM0372 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,092 | $25,000 | Implemented |
UM0372 # 06 Y:2010 | 06 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,702 | $3,500 | Implemented |
UM0372 # 07 Y:2010 | 07 | 2010 | COVER OPEN TANKS | $17,216 | $7,182 | Implemented |
UM0372 # 08 Y:2010 | 08 | 2010 | COVER OPEN TANKS | $10,159 | $500 | Implemented |
UM0372 # 09 Y:2010 | 09 | 2010 | COVER OPEN TANKS | $9,602 | $2,472 | Implemented |
UD0744 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $731 | $0 | Not Implemented |