Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
41
matching recommendationsNAICS | 332813 | Electroplating, Plating, Polishing, Anodizing, and Coloring |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0438 # 04 Y:2013 | 04 | 2013 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $98,045 | $175,000 | Not Implemented |
UM0438 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $22,608 | $7,500 | Not Implemented |
UM0438 # 02 Y:2013 | 02 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $945 | $600 | Not Implemented |
UM0438 # 01 Y:2013 | 01 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,260 | $350 | Not Implemented |
BD0437 # 02 Y:2013 | 02 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $87,468 | $54,000 | Not Implemented |
BD0437 # 11 Y:2013 | 11 | 2013 | USE POWER DURING OFF-PEAK PERIODS | $268 | $60 | Not Implemented |
BD0437 # 10 Y:2013 | 10 | 2013 | INSTALL OCCUPANCY SENSORS | $510 | $1,875 | Not Implemented |
BD0437 # 09 Y:2013 | 09 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,532 | $20 | Not Implemented |
BD0437 # 07 Y:2013 | 07 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $5,609 | $1,000 | Not Implemented |
BD0437 # 01 Y:2013 | 01 | 2013 | INCREASE EFFICIENCY OF TRUCKS | $168,734 | $780,000 | Not Implemented |
BD0437 # 03 Y:2013 | 03 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $33,735 | $100,000 | Not Implemented |
BD0437 # 04 Y:2013 | 04 | 2013 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $19,574 | $15,000 | Not Implemented |
BD0437 # 05 Y:2013 | 05 | 2013 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $7,315 | $20,000 | Not Implemented |
BD0437 # 08 Y:2013 | 08 | 2013 | INSTALL TURBULATORS | $5,570 | $2,600 | Not Implemented |
BD0437 # 06 Y:2013 | 06 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,643 | $10,000 | Not Implemented |
CO0675 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $270 | $290 | Implemented |
CO0675 # 01 Y:2013 | 01 | 2013 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $30,250 | $172,320 | Not Implemented |
CO0675 # 02 Y:2013 | 02 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,730 | $18,100 | Not Implemented |
CO0675 # 03 Y:2013 | 03 | 2013 | INSTALL OCCUPANCY SENSORS | $810 | $1,280 | Not Implemented |
IP0017 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $1,754 | $409 | Implemented |
IP0017 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $744 | $0 | Not Implemented |
IP0017 # 02 Y:2013 | 02 | 2013 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,701 | $0 | Implemented |
IP0017 # 03 Y:2013 | 03 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $805 | $0 | Implemented |
IP0017 # 10 Y:2013 | 10 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,437 | $9,348 | Implemented |
IP0017 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,167 | $1,400 | Implemented |