Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
31
matching recommendationsNAICS | 332813 | Electroplating, Plating, Polishing, Anodizing, and Coloring |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0913 # 07 Y:2014 | 07 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,485 | $5,000 | Not Implemented |
UD0913 # 06 Y:2014 | 06 | 2014 | REPLACE BOILER | $19,697 | $163,500 | Not Implemented |
UD0913 # 05 Y:2014 | 05 | 2014 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $1,623 | $7,000 | Not Implemented |
UD0913 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,643 | $8,500 | Not Implemented |
UD0913 # 03 Y:2014 | 03 | 2014 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $511 | $1,275 | Implemented |
UD0913 # 10 Y:2014 | 10 | 2014 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $414,555 | $27,000 | Not Implemented |
UD0913 # 12 Y:2014 | 12 | 2014 | TREAT AND REUSE RINSE WATERS | $15,837 | $10,000 | Not Implemented |
UD0913 # 11 Y:2014 | 11 | 2014 | USE DECANTING, FLOTATION TO REMOVE CONTAMINANTS | $27,921 | $55,000 | Not Implemented |
UD0913 # 09 Y:2014 | 09 | 2014 | INSTALL AUTOMATIC STACK DAMPER | $2,665 | $0 | Implemented |
UD0913 # 02 Y:2014 | 02 | 2014 | INSTALL OCCUPANCY SENSORS | $615 | $570 | Implemented |
UD0913 # 08 Y:2014 | 08 | 2014 | COVER OPEN TANKS | $3,270 | $6,780 | Implemented |
UD0913 # 01 Y:2014 | 01 | 2014 | UPGRADE CONVEYORS | $528 | $255 | Not Implemented |
MA0735 # 02 Y:2014 | 02 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,745 | $3,519 | Implemented |
MA0735 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,377 | $4,200 | Implemented |
MA0735 # 04 Y:2014 | 04 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,027 | $3,000 | Implemented |
MA0735 # 03 Y:2014 | 03 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,084 | $500 | Implemented |
MA0735 # 01 Y:2014 | 01 | 2014 | OPTIMIZE PLANT POWER FACTOR | $23,815 | $17,955 | Not Implemented |
MZ0148 # 02 Y:2014 | 02 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $549 | $850 | Not Implemented |
MZ0148 # 03 Y:2014 | 03 | 2014 | INSULATE BARE EQUIPMENT | $1,630 | $897 | Not Implemented |
MZ0148 # 04 Y:2014 | 04 | 2014 | INSULATE BARE EQUIPMENT | $546 | $2,000 | Implemented |
MZ0148 # 05 Y:2014 | 05 | 2014 | INSULATE BARE EQUIPMENT | $2,225 | $4,000 | Not Implemented |
MZ0148 # 06 Y:2014 | 06 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,573 | $1,700 | Not Implemented |
MZ0148 # 07 Y:2014 | 07 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $380 | $1,000 | Implemented |
MZ0148 # 01 Y:2014 | 01 | 2014 | USE PHOTOCELL CONTROLS | $1,021 | $980 | Implemented |
MZ0144 # 06 Y:2014 | 06 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,940 | $5,500 | Not Implemented |