Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
149
matching recommendationsNAICS | 3329 | Other Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0517 # 05 Y:2015 | 05 | 2015 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $5,974 | $8,760 | Not Implemented |
SD0517 # 06 Y:2015 | 06 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,975 | $9,935 | Not Implemented |
SD0517 # 07 Y:2015 | 07 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,154 | $2,000 | Implemented |
SD0517 # 08 Y:2015 | 08 | 2015 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $736 | $2,350 | Not Implemented |
SD0512 # 01 Y:2015 | 01 | 2015 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $34,138 | $61,820 | Not Implemented |
SD0512 # 02 Y:2015 | 02 | 2015 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,697 | $25,608 | Implemented |
SD0512 # 03 Y:2015 | 03 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $9,185 | $45,900 | Implemented |
SD0512 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,532 | $800 | Implemented |
SD0512 # 05 Y:2015 | 05 | 2015 | INSTALL OCCUPANCY SENSORS | $3,224 | $2,850 | Implemented |
SD0512 # 06 Y:2015 | 06 | 2015 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,985 | $5,247 | Implemented |
SD0484 # 01 Y:2014 | 01 | 2014 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $111,951 | $87,500 | Not Implemented |
SD0484 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,136 | $45,100 | Implemented |
SD0484 # 03 Y:2014 | 03 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,196 | $1,300 | Implemented |
SD0484 # 04 Y:2014 | 04 | 2014 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $6,896 | $400 | Implemented |
SD0484 # 05 Y:2014 | 05 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,758 | $300 | Implemented |
SD0484 # 06 Y:2014 | 06 | 2014 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,388 | $4,600 | Not Implemented |
SD0484 # 07 Y:2014 | 07 | 2014 | USE PHOTOCELL CONTROLS | $1,281 | $3,700 | Implemented |
SD0442 # 01 Y:2011 | 01 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $727 | $100 | Not Implemented |
SD0442 # 02 Y:2011 | 02 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,100 | $100 | Not Implemented |
SD0442 # 03 Y:2011 | 03 | 2011 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $247 | $30 | Not Implemented |
SD0442 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,022 | $1,900 | Not Implemented |
SD0442 # 05 Y:2011 | 05 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,760 | $26,500 | Not Implemented |
SD0442 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $597 | $1,566 | Not Implemented |
SD0440 # 01 Y:2011 | 01 | 2011 | ADD AREA LIGHTING SWITCHES | $157 | $100 | Not Implemented |
SD0440 # 02 Y:2011 | 02 | 2011 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,314 | $1,156 | Not Implemented |