Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
149
matching recommendationsNAICS | 3329 | Other Fabricated Metal Product Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0104 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $920 | $250 | Not Implemented |
LM0104 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,554 | $7,000 | Implemented |
LM0104 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,769 | $0 | Not Implemented |
SD0369 # 01 Y:2005 | 01 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $169,717 | $252,000 | Not Implemented |
SD0369 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,291 | $0 | Implemented |
SD0369 # 03 Y:2005 | 03 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,639 | $648 | Not Implemented |
SD0369 # 04 Y:2005 | 04 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,877 | $12,575 | Not Implemented |
SD0369 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,896 | $10,102 | Implemented |
SD0369 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $395 | $80 | Implemented |
SD0369 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $285 | $161 | Implemented |
SD0369 # 08 Y:2005 | 08 | 2005 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $12,744 | $17,000 | Not Implemented |
SD0367 # 01 Y:2005 | 01 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $15,944 | $23,500 | Not Implemented |
SD0367 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,834 | $15,130 | Not Implemented |
SD0367 # 03 Y:2005 | 03 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $7,652 | $8,000 | Not Implemented |
SD0367 # 04 Y:2005 | 04 | 2005 | COVER OPEN TANKS | $5,688 | $3,722 | Not Implemented |
SD0367 # 05 Y:2005 | 05 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,803 | $1,750 | Not Implemented |
SD0367 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,567 | $100 | Not Implemented |
SD0367 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $448 | $47 | Not Implemented |
SD0367 # 08 Y:2005 | 08 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $377 | $525 | Not Implemented |
SD0367 # 09 Y:2005 | 09 | 2005 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $663 | $60 | Not Implemented |
SD0367 # 10 Y:2005 | 10 | 2005 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $15,774 | $17,000 | Not Implemented |
LM0087 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,069 | $17,418 | Implemented |
LM0087 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,466 | $760 | Implemented |
LM0087 # 03 Y:2005 | 03 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,413 | $0 | Not Implemented |
LM0087 # 04 Y:2005 | 04 | 2005 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,685 | $450 | Not Implemented |