Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,258

matching recommendations
Reset
NAICS 3329 Other Fabricated Metal Product Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0272 # 03 Y:2003 03 2003 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $1,425 $190 Not Implemented
SF0272 # 04 Y:2003 04 2003 USE PHOTOCELL CONTROLS $4,362 $2,280 Not Implemented
SF0272 # 05 Y:2003 05 2003 RECOVER WASTE HEAT FROM EQUIPMENT $20,993 $20,000 Not Implemented
SF0272 # 06 Y:2003 06 2003 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $1,079 $812 Not Implemented
SF0272 # 07 Y:2003 07 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $521 $1,231 Not Implemented
WI0455 # 01 Y:2003 01 2003 $17,710 $2,500 Implemented
WI0455 # 02 Y:2003 02 2003 $12,503 $2,000 Not Implemented
WI0455 # 03 Y:2003 03 2003 INSTALL TIMERS AND/OR THERMOSTATS $1,687 $1,000 Not Implemented
WI0455 # 04 Y:2003 04 2003 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $1,787 $0 Not Implemented
WI0455 # 05 Y:2003 05 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,232 $1,240 Not Implemented
WI0455 # 06 Y:2003 06 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $716 $0 Not Implemented
LE0164 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,136 $150 Not Implemented
LE0164 # 02 Y:2003 02 2003 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $11,194 $4,000 Not Implemented
LE0164 # 03 Y:2003 03 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,205 $0 Not Implemented
LE0164 # 04 Y:2003 04 2003 INSTALL / REPAIR INSULATION ON STEAM LINES $175 $98 Not Implemented
LE0164 # 05 Y:2003 05 2003 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $5,397 $0 Not Implemented
LE0164 # 06 Y:2003 06 2003 COMBINE UTILITY METERS $864 $3,000 Not Implemented
LE0164 # 07 Y:2003 07 2003 COMBINE UTILITY METERS $3,442 $3,000 Not Implemented
LE0164 # 08 Y:2003 08 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,379 $149 Not Implemented
LE0164 # 09 Y:2003 09 2003 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $9,359 $5,100 Not Implemented
LE0164 # 10 Y:2003 10 2003 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,007 $1,050 Not Implemented
LE0164 # 11 Y:2003 11 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $14,436 $2,500 Not Implemented
BD0243 # 01 Y:2003 01 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $14,372 $2,000 Not Implemented
BD0243 # 02 Y:2003 02 2003 INSTALL OCCUPANCY SENSORS $13,962 $8,250 Implemented
BD0243 # 03 Y:2003 03 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,415 $1,200 Implemented